1. Introduction

VISITRAK is a wound measurement system
comprising three components:

VISITRAK Digital 

Battery powered 
digital measuring 
tablet with stylus.

VISITRAK Grid 

Single use, 3-layer 
tracing grid.

VISITRAK Depth 

Single use, foam 
tipped, sterile depth 
indicator.

VISITRAK enables the measurement of wound
dimensions (area, length, width and depth)
producing a visible record of the dimensions
of a wound. The digital tablet converts a line
tracing into a true area measurement and can
be used to calculate the % area change from
the last area measurement. It is also possible
to measure the % non-viable tissue (or other
regions in the wound).
VISITRAK is portable, easy to use and can be
used from patient to patient.

Indications for use

VISITRAK is indicated for wound area
measurement and can be used on all wound
types. VISITRAK Digital is indicated for use
only with VISITRAK Grid and VISITRAK Depth.
VISITRAK Digital will only function with the
attached stylus.

Warnings and Precautions

VISITRAK Digital

• Do not use the coversheet within / on a 

wound.

• Do not use VISITRAK Digital in a wet 

environment. Serious electrical damage 
may occur.

• Do not use VISITRAK Digital in the 

presence of flammable mixtures.

• Do not take apart VISITRAK Digital.
• Do not sterilise VISITRAK Digital. Damage 

or destruction to the device may result.

• Minimal pressure should be applied when 

tracing the wound outline onto the 
VISITRAK Digital with the stylus.

CAUTION: Misuse of the device will cause

inaccurate measurement and potential
damage.

VISITRAK Grid

• Do not fold or crease VISITRAK Grid.
• Not all pens are suitable for use on the 

tracing grid. Ensure that a permanent 
marker pen is used.

• Use minimal pressure when using a pen to

trace the wound edge.

• Do not touch the surface within the sealed

area of VISITRAK Grid. This surface will 
come in direct contact with the wound.

• Do not use the product if the seals are 

opened or damaged.

VISITRAK Depth
• Do not bend VISITRAK Depth.
• Only insert the foam tipped end into the 

wound.

• Rest the tip on the wound bed using 

minimal pressure. Care should be taken 
not to depress the wound bed.

2. Descriptions

Product Components:

VISITRAK Digital

(with batteries, replacement stylus nibs, nib removal ring and
coversheets)

Product Code  

Units

66000850      

1 per box

VISITRAK Grid

Product Code    

Units

66000851      

50 per carton

VISITRAK Depth

Product Code     

Units

66000852       

50 per carton

2

1

Wound area in cm

2

Wound length in cm (longest distance along vertical axis)

Wound width in cm (longest distance along horizontal axis)

Percent change in wound area

Percent non-viable tissue within the wound

Wound depth in cm (using VISITRAK Depth)

Patient name/identity

Date of measurement

Location of wound(s)

Clinician name/identity

Indicates the advised orientation of the film when measuring a wound,
so that the measurements taken are comparable

Peel this layer first

Peel this layer second

Symbols Guide

25˚C/

77˚F

SN

AA

/ LR6

9V        40mA

EXP.

LOT

STERILE 

EO

Open from this end

Store in a dry place

 

Do not reuse

Attention, see instructions for use

Store below 25˚C/77˚F

Lot number

Expiry date

Ethylene oxide sterilised

Battery type (1.5 volts – AA or LR6)

9 volts DC, 40 milliamps

In accordance with Electromagnetic
Compatibility Directive 89/336/EEC

Device Serial Number

Date of Manufacture

04

Содержание VISITRAK Depth

Страница 1: ...smith nephew VISITRAK Digital...

Страница 2: ...Seite 16 16 16 16 17 18 19 19 19 19 19 20 20 20 20 21 21 21 21 21 21 21 21 21 Indice 1 Introducci n Indicaciones de uso Avisos y precauciones Gu a de s mbolos 2 Descripciones Componentes del producto...

Страница 3: ...n ytt minen Suurempien haavojen pinta alan laskeminen useita ruudukoita Haava alueen muutoksen laskeminen Elinkelvottoman ja elinkelpoisen kudoksen prosenttiosuuden laskeminen VISITRAK Depth 4 Vianets...

Страница 4: ...old or crease VISITRAK Grid Not all pens are suitable for use on the tracing grid Ensure that a permanent marker pen is used Use minimal pressure when using a pen to trace the wound edge Do not touch...

Страница 5: ...f VISITRAK Depth as clinical waste 12 11 10 cm2 88 9 Remove the contaminated wound contact layer from the tracing grid quickly and carefully Dispose of as clinical waste Place the tracing grid on the...

Страница 6: ...more detailed instructions refer to the following pages NB A Calculate larger wounds using more than one tracing grid 1 Press here then measure the second wound by following steps 9 10 overleaf 2 Whe...

Страница 7: ...s not touched with the stylus for 8 minutes it will automatically power down and will have to be switched on using the power button A B C D E F cm2 0 0 cm2 88 9 cm 7 6 Width 3 Instructions for Use G c...

Страница 8: ...git Re enter the correct digits 18 When the area entered is correct touch OK 19 Assuming the new area is 88 9cm2 the unit will then display the change in area This cm2 i58 9 cm2 88 9 cm2 0 0 cm2 I27 0...

Страница 9: ...lus Do not lift the stylus while tracing and remain within the grid area Start and finish the tracing at the same point You will hear an audible BEEP to indicate a successful trace For large wound are...

Страница 10: ...plier ou plisser la grille VISITRAK Certains stylos ne peuvent tre employ s sur la grille S assurer qu un marqueur permanent est utilis Exercer une pression minimale en tra ant le pourtour de la plai...

Страница 11: ...nt l chelle gradu e La jauge de profondeur VISITRAK doit tre limin e avec les d chets cliniques 12 11 10 cm2 88 9 Enlever la couche de contact souill e de la grille rapidement et avec pr caution L lim...

Страница 12: ...ie de plaies dont la surface exc de celle d une seule grille 1 Appuyer ici puis calculer la mesure de la deuxi me grille en r p tant les tapes 9 et 10 au verso 2 Lorsque le traitement est termin l app...

Страница 13: ...2 0 0 cm2 88 9 3 Mode d emploi G cm2 0 0 cran de l appareil cm2 888 8 remettre l appareil en marche Calculer la superficie d une seule plaie 9 Si disponible placer la feuille protectrice sur la grille...

Страница 14: ...iffres 18 Lorsque la superficie saisie est correcte appuyer sur OK 19 Si on suppose que la nouvelle superficie est 88 9 cm2 l appareil affichera le pourcentage de changement de la superficie Dans notr...

Страница 15: ...n BIP audible lorsque le trac sera complet Dans le cas des plaies dont la surface exc de celle d une seule grille seule la superficie peut tre mesur e Toucher la grille avec le stylet pour r activer l...

Страница 16: ...atur oder jegliche Nutzung des Produkts zu einem anderen als dem bestimmungsgem en Zweck des Produkts macht diese Garantie nichtig GARANT A VISITRAK DIGITAL El proveedor Smith Nephew garantiza durante...

Страница 17: ...jen menetys goodwill arvon menetys tai muut vastaavat menetykset siit riippumatta miten ne aiheutuvat Kaikki mahdolliset muut nimenomaiset tai oletetut v itteet takuut tai ehdot siit riippumatta perus...

Страница 18: ...lding 237 2 Neung dong Kwangjin ku Seoul Korea 143 180 Tel 2343 60460 MALAYSIA Smith Nephew Sales Sdn Bhd Lot 11 Jalan 51A 223 46100 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 3 758 7103 MALTA V...

Отзывы: