4.2 Power supply
4.3 DC
output
4.4 Dynamic brake output
Mains voltage
230V AC ±15% 50/60 Hz
Type of power supply
Single-phase or three-phase
Maximum short-circuit current
5 kA at the installation point
Mains power supply absorption
28.2A RMS (single-phase power supply)
26.5A RMS (three-phase power supply)
Auxiliary mains voltage
24V DC -15 ÷ +20%
Auxiliary mains power supply max. ab-
sorption
30mA
The input current strictly depends on the line impedance; the values refer to sinusoidal
mains with generator impedance equal to zero. In real cases, the input current may undergo
a reduction up to 30%.
Rated voltage
325V DC not stabilized
Max output
current
16.0A (three-phase power supply)
9.0A (single-phase power supply)
Max output power
5.0 kW (three-phase power supply)
2.8 kW (single-phase power supply)
Braking resistor value range
20 Ω min.
Max braking power
About 10 kW
Average braking power
5 kW