IR lamp control module - HELCON 11XX series -
Installation, use and maintenance manual - EN
Ver. 1.02
38
• Reposition the fixing screws in place; sprinkle the stem of the upper fixing screw (the one that fixes the tab
of the electronic component to the fixing plate) with medium-type Loctite 243 type brakes or equivalent. Tight-
en the screws with a torque tool to a torque of 1.0 Nm ± 10%.
• Reconnect the connection cables in reverse order of disassembly.
• Reposition the plexiglass protection and fix it with the appropriate screws; tighten the screws with a torque
tool to a torque of 0.5 Nm ± 10%.
• Close the door.
9.3 Periodic maintenance - Tightening of the fuse holder terminals and power dividers
Tighten the power terminals at least every six months using the tightening torques and the tools shown in the
figure.
Current divider tightening torque
1.5 Nm with PZ2 insert
Fuse holder tightening torque
1.8 Nm with PZ2 insert
Current divider tightening torque
0.8 Nm with PZ1 insert