Instructions for the installer
36
Distances less than those indicated can cause risks to the structure and the
user.
6.3 Fitted installation (with barbecue)
After having aligned the height of the two products using the feet, the module can be installed following
the measurements provided and the following instructions:
MEASUREMENTS FOR EMBEDDED INSTALLATION OF THE MC30 BARBECUE
MODELS
MATERIAL
HEIGHT
MC30 + BQ60
MC30 + BQ60
NOT COMBUSTIBLE
A
910 mm
1210 mm
C
150 mm
150 mm
COMBUSTIBLE
B
920 mm
1220 mm
C
200 mm
200 mm
Distances less than those indicated can cause risks to the structure and the user.
It is possible reach the gas cylinder through a hole made in the structure (taking care to protect the edge
of the hole in order to avoid damaging the gas connection tube).
Bring the two products side by side, aligning their heights and depths without leaving any spaces
between them.
FRONT CROSS-SECTION
VIEW
SIDE CROSS-SECTION
VIEW
DISTANCES IF
SIDE WALLS PRESENT
HOLE FOR REAR
GAS CONNECTION
DISTANCE IF REAR
WALL PRESENT
OUTLETS
FOR ADDITIONAL
AIR INLETS
IF PRESENT
REAR
WALL
PASSAGE FOR LOWER
GAS CONNECTION
ONLY NON-COMBUSTIBLE MATERIAL
POSSIBLE LOWER
COMPARTMENT
DISTANCES FOR
ADDITIONAL AIR
INLETS