Instructions for the installer
48
3.2
Burner and nozzle characteristics table
Burner
Rated heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
(drawing ref. X238)
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.05
50
400
76
75
Semi rapid
1.8
65
500
131
129
Rapid
3.0
85
800
218
214
Fish Burner
1.9
68
800
138
136
Ultra rapid
3.9
100
1600
284
279
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Drawing
Ref.
Reduced capacity
(W)
Auxiliary
1.05
72
(X)
400
Semi rapid
1.8
97
(Z)
500
Rapid
3.0
115
(Y)
800
Fish Burner
1.9
94
(X)
800
Ultra rapid
3.9
135
(K)
1600
3.3
Arrangement of burners on cooking hob
BURNERS
1
Auxiliary
2
Semi rapid
3
Rapid
4
Ultra rapid
5
Fish burner