COD. 04041LT (Taiwan) - 04.03.2015
Instructions for the installation
and advice for the maintenance
EFX 30 1G AI AL TR 5
K
W - EFX 30 2G AI AL
Instructions Manual
Страница 1: ...COD 04041LT Taiwan 04 03 2015 Instructions for the installation and advice for the maintenance EFX 30 1G AI AL TR 5 KW EFX 30 2G AI AL Instructions Manual EFX 30 1G AI AL TR 5 KW EFX 30 2G AI AL ...
Страница 2: ...l knob Attention this appliance has been manufactured for domestic use only and it employment by private person To use the WOK pan support on ultra rapid gas burner only Put it on the ultra rapid pan support and make sure of the stability see fig A FIG A Model EFX 30 1G AI AL TR 5kW Model EFX 30 2G AI AL This cook top was designed to be used exclusively as a cooking appliance any other use such as...
Страница 3: ...ficiency with the least possible gas consumption use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal WARNINGS burners with flame failure device may only be ignited when the relative knob has been set to the ...
Страница 4: ...e this appliance any more or replace an old model before disposing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The ma...
Страница 5: ... have not become clogged by foreign bodies Check that enamelled burner cap C fig 6 and 6 A have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the cooktop Do not force the taps if they are difficult open or close Contact the technical assistance service for repairs Do...
Страница 6: ...fied personnel Never leave the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the cooktop will be installed are indicated in either fig 7 Always comply with the measurements given for the hole into which the appliance will ...
Страница 7: ...s of the strips must fit together without overlapping Evenly and securely fix the seal to the cooktop pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the bracket S stick on the top ...
Страница 8: ...manently ventilated in order to allow the appliance itself to operate correctly the necessary amount of air is that required for regular gas combustion and ventilation of the relative room the volume of which must not be less than 20 m3 Air must naturally flow through permanent openings in the walls of the room in question These openings must vent the fumes outdoors and their section must be at le...
Страница 9: ...shops and facilitates connection with the hose nipple of the pressure governor on the bottle With rubber hose pipe in compliance with standards The diameter of this hose pipe must be 8 mm and its length must be no less than 400 mm and no more than 1500 mm It must be firmly fixed to the hose nipple by means of the safety clamp specified by standards In case of liquid bottledgas supply mount a press...
Страница 10: ...ween the appliance and the electricity main This circuit breaker should be sized according to the load rating of the appliance and possess a minimum 3 mm gap between its contacts Remember that the earth wire must not be interrupted by the circuit breaker The electrical connection may also be protected by a high sensitivity differential circuit breaker You are strongly advised to fix the relative y...
Страница 11: ...aft In any case to access to regulation it can be done trought the insertion of a small screwdriver D beside the tap fig 12 or in the hole C inside the shaft of the tap fig 12 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low the lowest small flame should be continuous and steady Re assem...
Страница 12: ...sponding to the new gas regulation on the appliance instead of the already existing one This label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized Customer Care Department For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of the...
Страница 13: ...installer should leave the ground wire longer than the phase conductors fig 14 and comply with the recommendations given in paragraph 8 Gas cooktop H05 RR F Section 3 x 0 75 mm2 TYPE OF TYPE OF SINGLE PHASE COOKTOP CABLE POWER SUPPLY WARNING MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED PERSONS ...
Страница 14: ...kW Tot Nom Natural Gas Rate 5 0 kW Tot Nom L P G Rate 364 g h Voltage 110 V Frequency 60 Hz 14 2 BURNERS 30 Rapid auxiliary Category II23 LPG 280 mmH2O NATURAL 150 mmH2O Tot Nom L P G Gas Rate 4 0 kW Tot Nom Natural Gas Rate 4 0 kW Tot Nom L P G Rate 291 g h Voltage 110 V Frequency 60 Hz TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION ...
Страница 15: ...15 ...
Страница 16: ...r or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centers and authorized retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packin...