Page 21 of 52
5.6
SHUTDOWN
Machine shutdown is carried out when the user presses the blue main switch found under
the flap on the right.
This switch is lit up when the machine is one and is off when the machine is switched off.
Do not switch off the machine during a cycle. The sterilization process in progress will
be invalid when this happens. When the machine is restarted after a sudden shutdown,
once the cycle in progress is completed, the machine will behave in the same way as if it
had been shut down suddenly due to a black-out (see the following paragraph).
Also when interrupting a sterilization process in progress is necessary, we recommend
proceeding with a forced interruption (see the following "cycle interruption" paragraph).
5.7
RECOVERY AFTER A SUDDEN BLACK-OUT
In the event of a power failure during any sterilization cycle phase, when the machine is
turned back on, it will complete the end of the preceding cycle in progress, discharging the
pressure in the chamber and drying.
Sterilization should not be considered valid, the machine will enter into safe conditions and
the interface will guide the user through procedures to return to initial conditions with the
door open.
Once procedure resetting has been completed, the machine will be ready for a new
sterilization cycle to be turned on.
5.8
TANK MANAGEMENT
fig. 17 – front connections for water load/discharge
The B-One sterilizer is equipped with two tanks: