-15-
4. Maintenance
1. Perform maintenance regularly and clean the emitters. (every 2 weeks suggested.).
The maintenance must be performed by an operator who has sufficient knowledge and experience.
If the ionizer is used for a long time and there is dust on the electrodes, performance of the product will
be reduced. When the NDL LED (maintenance signal LED) is ON,the emitter will need to be cleaned. If
the emitter gets worn and static electricity elimination ability does not recover even after cleaning,
replace the emitter.
2. Before starting inspection, cleaning or replacing the emitter, or replacing the valves, be sure to
turn OFF the power and air supply to the main body.
If the emitter is touched while the product is energized, this may cause an electric shock or accident.
3. Do not disassemble or modify the product.
This may lead to accidents such as electric shock, failure, fire or etc. If the product is disassembled
and/or modified, the functions and performance in the specifications may not be achieved and the
product will not be guaranteed.
4. Do not operate the product with wet hands.
This may cause an electric shock or accident.
4.1 Maintenance of Ionizer
4.1.1 Emitter cleaning
1. Rotate the handle of the emitter assembly by hand and remove it.
2. Ionizer emitter cleaning kit: The emitter is cleaned with IZS30-M2.
3. Insert the emitter assembly back to the port using caution not to damage the end of the emitter, and
screw it in.
Note)
4.1.2 Replacement of Emitter
1. Rotate the handle of the emitter assembly by hand and remove it.
2. Replace it with a new emitter assembly.
3. Insert the emitter assembly back to the port using caution not to damage the end of the emitter, and
screw it in.
Note)
Notes:
- Screw in the emitter assembly completely until the handle of the emitter assembly gets into close contact
with the mounting surface of the body.
- If the ionizer nozzle touches the inner surface of the hole on the desktop duster box body after mounting
the
electrode assembly, adjust the angle of the ionizer nozzle not to touch it.
- Use caution not to get injured with the end of the emitter.
A high voltage generating circuit is mounted onto this product. Verify that the power
supply is OFF when performing maintenance. Never disassemble or modify the
product, as this can cause loss of product functionality, and there is also a risk of
electric shock and earth leakage.
High voltage caution
Emitter assembly
(Single part No.:
IZN10-NT-X325)
Handle
Ionizer nozzle
ル