manualshive.com logo in svg
background image

SMCCO10-Z CO Alarm User Guide 

 

Copyright 

©

2013 SMC Networks

  

Page 10 

 

All Rights Reserved 

I/M SMCC010-Z rev. 1.0 

1/23/2013 

9/3/10 

 

 

B.

 

Perform steps A through D in Step 6, 
“Adding to the Touchscreen” on 
page 3. 

C.

 

At the Technician Settings menu, 
select 

Sensors & Zones > Delete a 

Sensor/Zone

. The Premise 

Passphrase keyboard appears. 

D.

 

Enter the Premise Passphrase and 
click 

Done

. The currently installed 

sensors/security zones appear. 

E.

 

Tap the zone you want to delete 
and follow the instructions on the 
Touchscreen to delete the 
SMCCO10-Z and security zone from 
the current system. 

11  

 

Troubleshooting 

SMCCO10-Z does not power up 
properly or reports low battery 

 

Be sure the batteries are fully 
seated within the battery 

compartment and the polarity is 
correct. 

 

Check the battery voltage (1.5 VDC 
nominal per battery). 

Touchscreen does not respond 

 

Use a wireless RF sniffer to confirm 
that the SMCCO10-Z is sending 
messages for activation. 

 

Be sure the SMCCO10-Z is enrolled 
into the Touchscreen properly. 

 

Be sure you are using a compatible 
Touchscreen (see “Specifications” 
on page 11). 

Tamper condition does not restore 

 

Be sure the SMCCO10-Z is installed 
on the mounting plate properly and 
the mounting plate has a magnet. 

 

Be sure there are no trouble 
indications at the CO alarm. 

 

Be sure you are using a compatible 
Touchscreen (see “Specifications” 
on page 11). 

If a tamper alarm occurs 

 

Be sure you are using a compatible 
Touchscreen (see “Specifications” 
on page 11). 

 

Be sure the Touchscreen is in sensor 
test mode during sensor testing. 

Alarm/open condition does not restore 

 

Be sure the smoke or heat has 
cleared the SMCCO10-Z. 

 

Be sure you are using a compatible 
Touchscreen (see “Specifications” 
on page 11).

Содержание SMCCO10-Z

Страница 1: ...the system is monitored The SMCCO10 Z also detects low battery wall tamper and sensor end of life These trouble codes are sent to the Touchscreen which reports the condition to the central monitoring...

Страница 2: ...dren Never allow children to handle the SMCCO10 Z Figure 1 Recommended Locations Locations to Avoid Selecting an improper location can affect the sensitive electronic components in your SMCCO10 Z To a...

Страница 3: ...A Log in to the Settings app with an Installer code B In the Settings menu tap Sensors Zones Add a Sensor Zone C Place the SMCCO10 Z in Search mode and prepare it to be added to the Touchscreen refer...

Страница 4: ...Sensors screen M If all sensors have not been configured the Modify screen appears for each sensor to let you review its details Change the details as needed or tap Next to cycle through all the sens...

Страница 5: ...ded Place one label next to the SMCCO10 Z after it is mounted and the other label near a fresh air source such as a door or window 5 Installng RepacingBatteries The SMCCO10 Z comes with 3 batteries pr...

Страница 6: ...uct is sealed and its cover is not removable The SMCCO10 Z alarm has 3 test modes Normal CO alarm test conducts an internal self test and tests the sounder See Running the Normal CO Alarm Test on page...

Страница 7: ...ion A Be sure the SMCCO10 Z is operating normally and the green Power LED is flashing once every 30 seconds B Wait at least 10 minutes after installing the SMCCO10 Z C Set the Touchscreen to sensor te...

Страница 8: ...ow When CO is detected the SMCCO10 Z activates a CO alarm The SMCCO10 Z sends RF test packets to the Touchscreen when the CO alarm activates Figure 6 CO Testing Slit F The Touchscreen beeps and shows...

Страница 9: ...stem is disarmed The system continues to log the activity of bypassed zones in the Event History see View Zone Event History on this page To bypass a zone A With the system disarmed tap the Security a...

Страница 10: ...correct Check the battery voltage 1 5 VDC nominal per battery Touchscreen does not respond Use a wireless RF sniffer to confirm that the SMCCO10 Z is sending messages for activation Be sure the SMCCO1...

Страница 11: ...Standby Current 35 A typically Battery Life 5 years typically Sensor Life 10 years Alarm Response Time 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min Audible alarm 85 dBa 10 3M temporal 4 Low B...

Страница 12: ...Test Hush button and release to silence the end of life signal for up to 3 days After 3 days unit resumes end of life chirps Hush mode silences the alarm 10 times or up to 30 days After 30 days the un...

Страница 13: ...solvents to clean the SMCCO10 Z They can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or other aerosols near the product Do not paint the SMC...

Страница 14: ...t you to the presence of CO before most people would experience symptoms of CO poisoning giving you time to resolve the problem calmly Determine whether anyone is experiencing symptoms of CO poisoning...

Страница 15: ...sent the sooner the alarm is triggered Your SMCCO10 Z can only warn you about the presence of CO It does not prevent CO from occurring and cannot solve existing CO problems If your SMCCO10 Z has alarm...

Страница 16: ...its It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is not suitable for installation in hazardous locations as de...

Страница 17: ...ompliant This product does not contain lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB or polybrominated depheny ethers PBDE in more than the percentage specified by EU directive...

Отзывы: