Maintenance Tips 

The SMCCO10-Z is designed for a long 
service life of 10-years. Although the 
Touchscreen might indicate when to 
service the SMCCO10-Z, several checks 
are recommended.  

 

Weekly - CO Alarm Test. 

 

Annual - CO Alarm Functional Gas 
Test. 

 

Random - visual check for green 
Power LED flashing every 30 seconds 
and for wireless signal strength. 

Touchscreen indications are Trouble and 
Low Battery. 

 

Trouble - SMCCO10-Z has an internal 
fault requiring technical service. 

 

Low Battery - batteries must be 
replaced for proper operation.  

General Tips 

 

Vacuum the SMCCO10-Z cover each 
month to remove accumulated dust.  

 

Never use detergents or solvents to 
clean the SMCCO10-Z. They can 
permanently damage or temporarily 
contaminate the sensor.  

 

Avoid spraying air fresheners, hair 
spray, paint, or other aerosols near 
the product.  

 

Do not paint the SMCCO10-Z. Paint 
will seal the vents and interfere 
with proper sensor operation.  

 

Move the SMCCO10-Z to a remote 
location to prevent possible damage 
or contamination prior to: 
 
Staining or stripping floors or 
furniture, painting or wall-papering.  
 
Using aerosols or adhesives.  

WARNING:

 Reinstall the SMCCO10-Z as 

soon as possible for continuous 
protection. 

The following substances can damage the 
SMCCO10-Z or cause temporary readings 
that are not CO readings: 

 

Ethylene 

 

Ethanol 

 

Alcohol 

 

Iso-propanol 

 

Benzene 

 

Toluene 

 

Ethyl acetate 

 

Hydrogen 

 

Hydrogen sulfide 

 

Sulfur dioxide 

Included in this list are most: 

 

Aerosol sprays 

 

Alcohol-based 

products 

 

Paints, thinners, 

solvents, and 
adhesives 

 

Hair sprays, 

after shaves, 
and perfumes 

 

Auto exhausts 
(cold start) 

 

Some cleaning 
agents 

Содержание SMCCO10-Z

Страница 1: ...the system is monitored The SMCCO10 Z also detects low battery wall tamper and sensor end of life These trouble codes are sent to the Touchscreen which reports the condition to the central monitoring...

Страница 2: ...dren Never allow children to handle the SMCCO10 Z Figure 1 Recommended Locations Locations to Avoid Selecting an improper location can affect the sensitive electronic components in your SMCCO10 Z To a...

Страница 3: ...A Log in to the Settings app with an Installer code B In the Settings menu tap Sensors Zones Add a Sensor Zone C Place the SMCCO10 Z in Search mode and prepare it to be added to the Touchscreen refer...

Страница 4: ...Sensors screen M If all sensors have not been configured the Modify screen appears for each sensor to let you review its details Change the details as needed or tap Next to cycle through all the sens...

Страница 5: ...ded Place one label next to the SMCCO10 Z after it is mounted and the other label near a fresh air source such as a door or window 5 Installng RepacingBatteries The SMCCO10 Z comes with 3 batteries pr...

Страница 6: ...uct is sealed and its cover is not removable The SMCCO10 Z alarm has 3 test modes Normal CO alarm test conducts an internal self test and tests the sounder See Running the Normal CO Alarm Test on page...

Страница 7: ...ion A Be sure the SMCCO10 Z is operating normally and the green Power LED is flashing once every 30 seconds B Wait at least 10 minutes after installing the SMCCO10 Z C Set the Touchscreen to sensor te...

Страница 8: ...ow When CO is detected the SMCCO10 Z activates a CO alarm The SMCCO10 Z sends RF test packets to the Touchscreen when the CO alarm activates Figure 6 CO Testing Slit F The Touchscreen beeps and shows...

Страница 9: ...stem is disarmed The system continues to log the activity of bypassed zones in the Event History see View Zone Event History on this page To bypass a zone A With the system disarmed tap the Security a...

Страница 10: ...correct Check the battery voltage 1 5 VDC nominal per battery Touchscreen does not respond Use a wireless RF sniffer to confirm that the SMCCO10 Z is sending messages for activation Be sure the SMCCO1...

Страница 11: ...Standby Current 35 A typically Battery Life 5 years typically Sensor Life 10 years Alarm Response Time 70 PPM 60 240 min 150 PPM 10 50 min 400 PPM 4 15 min Audible alarm 85 dBa 10 3M temporal 4 Low B...

Страница 12: ...Test Hush button and release to silence the end of life signal for up to 3 days After 3 days unit resumes end of life chirps Hush mode silences the alarm 10 times or up to 30 days After 30 days the un...

Страница 13: ...solvents to clean the SMCCO10 Z They can permanently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or other aerosols near the product Do not paint the SMC...

Страница 14: ...t you to the presence of CO before most people would experience symptoms of CO poisoning giving you time to resolve the problem calmly Determine whether anyone is experiencing symptoms of CO poisoning...

Страница 15: ...sent the sooner the alarm is triggered Your SMCCO10 Z can only warn you about the presence of CO It does not prevent CO from occurring and cannot solve existing CO problems If your SMCCO10 Z has alarm...

Страница 16: ...its It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards It is not suitable for installation in hazardous locations as de...

Страница 17: ...ompliant This product does not contain lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB or polybrominated depheny ethers PBDE in more than the percentage specified by EU directive...

Отзывы: