Warning
Caution
Manual Override
How to Attach and Detach a Connector
Mounting of Valves
Series
S0700
Specific Product Precautions 1
Be sure to read before handling.
Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port
Solenoid Valve Precautions.
Push down on the manual override button with a small screwdriver
until it stops.
The manual override is used for switching the main
valve.
Push type (Tool required)
Bore ø
3.2
Bore ø
3.2
Plug-in
Plug lead
Note) In order not to damage the connector and cover, do not pull the lead wire
excessively (with a force of 10 N or more).
<Plug lead type only>
To attach a connector, hold the lever and connector unit between
your fingers and insert straight onto the pins of the solenoid valve
so that the lever’s pawl is pushed into the groove and locks.
To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the con-
nector straight out.
Lever
Connector
Cover
Lever pawl
Groove
Proper torque N
폷
m
0.17 to 0.23
Tighten the bolts firmly to stop the gasket from com-
ing away from the valve using the appropriate torque
as shown on the following table.
Mounting screw (M2)
Mounting screw (M2)
Plug-in
Plug lead
671
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 671