S
SS0750
SDA2
08 C4
B
Voltage: 24 VDC
S07 1 0
5
Base mounted plug-in
EX
50
0
ser
ies
Note) Not compatible with dual 3 port valves.
Refer to pages 1680 to 1694 for the details of EX500 gateway system
serial transmission system.
S0700
Kit (Serial Transmission)
EX500 Gateway System Serial Transmission System
How to Order Manifold
Cylinder port size
Symbol
C2
C3
C4
CM
N1
N3
NM
Port size
With one-touch fitting for ø2
With one-touch fitting for ø3.2
With one-touch fitting for ø4
Mixed size/with port plug
Note)
With one-touch fitting for ø1/8"
With one-touch fitting for ø5/32"
Mixed size/with port plug
Note)
Metric
Inch
Stations
Symbol
01
16
Stations
1 station
16 stations
Note) The maximum number of stations will be dif-
ferent depending on the wiring specification.
···
···
Note)
Note) Specify “Mixed size/with port plug” in the manifold
specification sheet.
Nil
B
Note 2)
D
D0
D
Note 3)
K
Note 4)
N
R
Note 5)
S
Stations
None
With back pressure check valve (all stations)
With DIN rail (Rail length: Standard)
Without DIN rail (with bracket)
With DIN rail Designated length (
: station)
Special wiring specification (Except double wiring)
With name plate
External pilot
Built-in silencer
Option
Note 1) When two or more options are specified, indicate them alphabetically.
Example) -BRS
Note 2) When installing a back pressure check valve on the required station, enter
the part number and specify the station position in the manifold specification
sheet.
Note 3) The available number of stations is larger than the number of manifold
stations.
Note 4) Indicate the wiring specification for mixed single and double wirings.
Note 5) For details, refer to page 648.
∗
For manifold optional parts, refer to pages 648 to 652.
∗
For manifold exploded view, refer to page 654.
Symbol
Kit name
1 to 8 stations
Decentralized serial wiring
serial transmission
S kit
Kit name
Specification
Symbol
Without serial unit
DeviceNet, PROFIBUS DP, CC-Link, EtherNet/IP
Standard station
Max. number of
stations for special
wiring specification
16 stations
Max. number of
solenoids
16
SD0
SDA2
Note 1) The maximum number of stations is determined by the total number of solenoids.
For mixed single and double wirings, enter “-K” to the order code options.
Note 2) For SI unit part number, refer to page 655.
Single type
1
Double, Dual 3 port type
2
Type of actuation
Number of solenoids
SI unit COM.
SI unit COM.
+COM.
–COM.
N
EX500
Note) Without SI unit (SD0), the symbol is nil.
Nil
DeviceNet
PROFIBUS DP
CC-Link
EtherNet/IP
How to Order Valves
Type of actuation
Note) For JIS symbol, refer to page 616.
Symbol
1
2
A
B
C
Specification
2 position single
2 position double
4 position dual 3 port type (N.C. + N.O.)
4 position dual 3 port type (N.O. + N.O.)
[Pressure center]
4 position dual 3 port type (N.C. + N.C.)
[Exhaust center]
Specification
Standard
External pilot
Note)
Symbol
Nil
R
Function
1 set – Manifold base part no.
3 sets – Valve part no. (Stations 1 to 3)
2 sets – Valve part no. (Stations 4 to 5)
2 sets – Valve part no. (Stations 6 to 7)
1 set – Blanking plate part no. (Station 8)
SS0750-08C4SDA2 ·····
∗
S0710-5 ····················
∗
S0720-5 ····················
∗
S07A0-5 ···················
∗
SS0700-10A-1 ··········
How to Order Manifold Assembly
<Example>
Serial transmission kit
Specify the part numbers for valves and
options together beneath the manifold base
part number.
Prefix the asterisk to
the part nos. of the
solenoid valve, etc.
Write sequentially from the
1st station on the D side.
When part nos. written
collectively are complicated,
specified by using the
manifold specification sheet.
1 2 3 ······ S
tations
D side
U side