Valve Specifications
Valve Specifications
Model
Series
Type of
actuation
Flow characteristics
Cv
Plug-in type
2 position
4 position
2 position
4 position
Plug lead
type
Single
Double
Dual 3 port
valve
Single
Double
Dual 3 port
valve
Model
S0710
S0720
S07 0
S0715
S0725
S07 5
A
B
C
A
B
C
Note 2)
Response
time (msec)
Mass
(g)
0.10
0.10
0.08
0.10
0.10
0.08
b
0.39
0.39
0.33
0.39
0.39
0.33
C[dm
3
/(s·bar)]
0.37
0.37
0.33
0.37
0.37
0.33
18 or less
10 or less
18 or less
12 or less
10 or less
12 or less
30
38
38
28
36
36
4/2
→
5/3 (A/B
→
R1/R2)
Cv
0.11
0.11
0.09
0.11
0.11
0.09
b
0.39
0.39
0.34
0.39
0.39
0.34
C[dm
3
/(s·bar)]
0.39
0.39
0.34
0.39
0.39
0.34
1
→
4/2 (P
→
A/B)
Valve construction
Fluid
Max. operating pressure
Min. operating pressure
Ambient and fluid temperature
Max. operating cycle
Pilot valve exhaust method
Pilot valve manual override
Lubrication
Impact resistance/Vibration
resistance
Note 3)
Enclosure
Coil rated voltage
Allowable voltage fluctuation
Coil insulation type
Power consumption
(Current)
Rubber seal
Air/Inert gas
0.7 MPa
0.2 MPa
–10 to 50
°
C
Note 1)
5 Hz
Push type
Not required
30/100 m/s
2
IP40
24 VDC
±
10% of rated voltage
Class B or equivalent
DC 0.35 W (15 mA)
Plug-in type
Common exhaust
Note 2)
24 VDC
Plug lead type
Individual exhaust
Standard Specifications
Note 1) The value for cylinder port fitting port size C6.
Note 2) Based on JIS B 8375-1993 (Supply pressure: 0.5 MPa, with indicator light and surge voltage suppressor, clean air. This will change depending on pressure and air quality.)
The value when ON for the double type.
Valve specification
Electrical
specification
Use dry air to prevent condensation when operating at low temperatures.
Valves with the external pilot specifications have a pilot EXH with individual exhaust specifications.
Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and de-
energized states every once for each condition.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000 Hz. Test
was performed at both energized and de-energized states in the axial direction
and at the right angles to the main valve and armature.
Note 1)
Note 2)
Note 3)
614
P0609-P0680-E080904.qxd 08.9.4 11:34 AM Page 614