SMC Networks PSE200 Series Скачать руководство пользователя страница 18

1. Confirm the specifications.

Products represented in this catalog are designed for use in 
compressed air appllications only (including vacuum), unless 
otherwise indicated.
Do not use the product outside their design parameters.
Please contact SMC when using the products in applications 
other than compressed air (including vacuum).

4. Use clean air

If the compressed air supply is contaminated with chemicals, 
cynthetic materials, corrosive gas, etc., it may lead to break 
down or malfunction.

Selection

Mounting

Piping

Air Supply

Maintenance

Operating Environment

Warning

1. Instruction manual

Install the products and operate them only after reading the 
instruction manual carefully and understanding its contents. 
Also keep the manual where it can be referred to as 
necessary.

2. Securing the space for maintenance

When installing the products, please allow access for 
maintenance.

3. Tightening  torque

When installing the products, please follow the listed torque 
specifications.

Warning

1. Do not use in environments where the product 

is directly exposed to corrosive gases, 
chemicals, salt water, water or steam.

2. Do not expose the product to direct sunlight 

for an extended period of time.

3. Do not use in a place subject to heavy 

vibrations and/or shocks.

4. Do not mount the product in locations where it 

is exposed to radiant heat.

Warning

1. Maintenance procedures are outlined in the 

operation manual.

Not following proper procedures could cause the product to 
malfunction and could lead to damage to the equipment or 
machine.

2. Maintenance work

If handled improperly, compressed air can be dangerous.
Assembly, handling and repair of pneumatic systems should 
be performed by qualified personnel only.

3. Drain flushing

Remove drainage from air filters regularly. (Refer to the 
specifications.)

4. Shut-down before maintenance

Before attempting any kind of maintenance make sure the 
supply pressure is shut of and all residual air pressure is 
released from the system to be worked on.

5. Start-up after maintenance and inspection

Apply operating pressure and power to the equipment and 
check for proper operation and possible air leaks. If operation 
is abnormal, please verify product set-up parameters.

6. Do not make any modifications to be product.

Do not take the product apart.

Warning

1. Before piping

Make sure that all debris, cutting oil, dust, etc, are removed 
from the piping.

2. Wrapping of pipe tape

When screwing piping or fittings into ports, ensure that chips 
from the pipe threads or sealing material do not get inside the 
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread 
ridges exposed at the end of the threads.

Caution

1. Operating fluid

Please consult with SMC when using the product in 
applications other than compressed air (including vacuum).
Regarding products for general fluid, please ask SMC about 
applicable fluids.

2. Install an air dryer, aftercooler, etc.

Excessive condensate in a compressed air system may cause 
valves and other pneumatic equipment to malfunction.
Installation of an air dryer, after cooler etc. is recommended.

3. Drain flushing

If condensate in the drain bowl is not emptied on a regular 
basis, the bowl will over flow and allow the condensate to 
enter the compressed air lines.
If the drain bowl is difficult to check and remove, it is 
recommended that a drain bowl with the auto-drain option be 
installed.
For compressed air quality, refer to “Air Preparation 
Equipment” catalog.

Warning

Common Precautions

Be sure to read before handling.
For detailed precautions on every series, refer to main text.

16-14-4

SHOP ONLINE at www.airlinehyd.com

800-999-7378

Содержание PSE200 Series

Страница 1: ...dapter 48 conversion adapter Mounting screws M3 x 8L Accessory Panel Power supply Output connection cable ZS 26 A Included with the controller Front protective cover Option When only optional parts ar...

Страница 2: ...sation Operating Stored 35 to 85 RH No condensation 10 to 500 Hz at whichever is smaller of 1 5 mm amplitude or 98 m s2 acceleration in X Y Z directions for 2 hrs each De energized 980 m s2 in X Y Z d...

Страница 3: ...1 5 Gray CH2_OUT1 4 White CH1_OUT2 3 Black CH1_OUT1 2 Blue DC 1 Brown DC Power supply Output connection cable Included 2000 Power supply Output connector 8P PIN no Terminal DC DC CH1_OUT1 CH1_OUT2 CH2...

Страница 4: ...nel fitting dimension Applicable panel thickness 0 5 to 8 mm 55 or more 37 5 0 1 0 2 55 or more Waterproof seal Waterproof seal Panel Panel mount adapter 48 conversion adapter Panel Panel mount adapte...

Страница 5: ...onnection PSE200 M NPN open collector 5 outputs Auto shift 1 input specification PSE201 M PNP open collector 5 outputs Auto shift 1 input specification 12 to 24 VDC DC Sensor input 1 to 5 VDC DC N C D...

Страница 6: ...ure range Applicable pressure sensor Sensor supply pressure 101 to 101 kPa PSE533 10 to 101 kPa PSE531 10 to 101 kPa PSE532 0 1 to 1 MPa PSE530 Pressure Sensor Sensor Range Compound pressure Vacuum Lo...

Страница 7: ...al pressures by changing the response time setting Principle The pressure values measured within the response time that is selected by the user are averaged By comparing this average pressure value wi...

Страница 8: ...d the set value Switch output 1 2 P1 P2 P3 P4 ON OFF Hysteresis Hysteresis Normally closed Note The hysteresis is set to 3 digits When setting the pressure allow 7 digits or more Note 1 If the hystere...

Страница 9: ...the equipment to be set in this mode In the case where OUT1 setting is not required In the case where OUT2 setting is not required OUT1 auto preset For adsorption verification In this mode repeat the...

Страница 10: ...MPa OUT2 1 2 3 4 OUT1 PRESSURE SET CH kPa MPa OUT2 1 2 3 4 OUT1 SET SET SET Copy mode Copy mode Selection of the channel to be copied Selection of the channel to be copied to Copy mode or Setting is...

Страница 11: ...OUT1 Auto identification mode Auto identification mode ON To measuring mode or On Off CH3 3 Auto shift 4 Auto identification On Off CH2 Displays alternately On Off CH1 On Off CH4 Setting is complete...

Страница 12: ...pressure erroneous operation may occur e g in the case of adsorption verification the switch does not turn ON even though the workpiece is being adsorbed or does not turn OFF even though the workpiec...

Страница 13: ...To return to the measuring mode press Bottom value blinks Peak Bottom display Press and hold for 2 seconds or longer SET SET SET SET If any buttons other than above are pressed during the peak bottom...

Страница 14: ...unctions may occur due to noise from these other lines 4 If a commercial switching regulator is used make sure that the F G terminal is grounded Connection Warning 1 Our multi channel pressure sensor...

Страница 15: ...nserted all the way temporarily hold the connector down manually Using pliers snap A into B as shown below so that there is no gap between A and B and secure the connector The A and B portion of the s...

Страница 16: ...O D 1 0 to 1 4 1 4 to 2 0 1 0 to 1 4 1 4 to 2 0 Sensor part no PSE510 PSE530 PSE521 PSE520 Brown Black Blue N C 1 2 3 4 F G Regulating Pressure Range Rated Pressure Range 1 Regulating pressure range R...

Страница 17: ...3 Do not service machinery equipment or attempt to remove components until safety is confirmed 1 Inspection and maintenance of machinery equipment should only be performed once measures to prevent fal...

Страница 18: ...y 3 Drain flushing Remove drainage from air filters regularly Refer to the specifications 4 Shut down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut...

Страница 19: ...rd related to environmental management systems and environmental inspections While promoting environmentally friendly automation technology SMC is also making diligent efforts to preserve the environm...

Страница 20: ...chinery Directive contains essential health and safety requirements for machinery as applied to industrial machines e g machine tools injection molding machines and automatic machines Pneumatic equipm...

Страница 21: ...d for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards The above CSA NRTL C logo is described on a product label in order to indic...

Страница 22: ...irmatic Ltda Calle 18 69 05 Apart Aereo 081045 Santa Fe de Bogot Colombia TEL 1 424 9240 FAX 1 424 9260 U K SMC Pneumatics U K Ltd Vincent Avenue Crownhill Milton Keynes MK8 0AN Backinghamshire U K TE...

Страница 23: ...ngton Auckland New Zealand TEL 09 573 7007 FAX 09 573 7002 TAIWAN SMC Pneumatics Taiwan Co Ltd 17 Lane 205 Nansan Rd Sec 2 Luzhu Hsiang Taoyuan Hsien TAIWAN TEL 03 322 3443 FAX 03 322 3387 HONG KONG S...

Отзывы: