background image

 

-13- 

 

No.PF

※※

-OMN0010-J   

 

 

Lead wire 

NIL 

With M8 connector and lead wire 

 

With M8 connector and no lead wire 

 

 

Bracket 

NIL 

Without bracket 

 

With bracket 

 

With flow adjustment valve 

 

 

Options/Part number 

If an option is required independently, order using the following part number. 

Option 

Part number 

Remarks 

Bracket 

 

ZS-40-K 

Taptite screw for PF3W504/520 (3 x 8), 4 pcs. 

ZS-40-L 

Taptite screw for PF3W540 (3 x 8), 4 pcs. 

ZS-40-M 

Taptite screw for PF3W511 (4 x 10), 4 pcs. 

Lead wire with M8 connector 

ZS-40-A 

Lead wire length: 3 m 

: 2 brackets are necessary if using the type with flow rate adjustment valve. Bracket cannot be mounted onto the 250 L/min type. 

 

Replacement part 

Element 

Part number 

Remarks 

Vinyl chloride piping tube (25 A) 

ZS-40-U25 

25 A Vinyl chloride piping tube 1 pc. 

Vinyl chloride piping tube (30 A) 

ZS-40-U30 

30 A Vinyl chloride piping tube e 1 pc. 

25 A Holding plate 

ZS-40-U25-A 

1 pc., With two hexagon socket head cap screws of M5 x 80. 

30 A Holding plate 

ZS-40-U30-A 

1 pc., With two hexagon socket head cap screws of M5 x 65. 

: Accuracy may vary by 1 to 2%, if vinyl chloride piping tube is replaced. 

Содержание PF3W5 Series

Страница 1: ...No PF OMN0010 J PRODUCT NAME Digital Flow Switch Remote type sensor unit MODEL Series Product Number PF3W5...

Страница 2: ...r 11 Summary of Product parts 14 Definition and terminology 15 Mounting and Installation 16 Installation 17 Piping 19 Wiring 22 Flow Measurement 23 Maintenance 24 Troubleshooting 25 Specification 28 S...

Страница 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Страница 4: ...the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excl...

Страница 5: ...ion or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not...

Страница 6: ...nction can result Insufficient supply voltage may not drive a load due to a voltage drop inside the product Verify the operating voltage of the load before use Do not exceed the specified maximum allo...

Страница 7: ...in the piping will be disturbed leading to improper measurement Therefore the above mentioned piping should be connected on the OUT side If the OUT side is opened or flow rate is excessive cavitations...

Страница 8: ...uct Do not perform wiring while the power is on Otherwise damage to the internal parts can result causing malfunction Do not route wires and cables together with power or high voltage cables Otherwise...

Страница 9: ...to lightning strikes Take measures against lightning strikes in the system Mount the product in a location that is not affected by vibration or impact Otherwise failure or malfunction can result Do no...

Страница 10: ...use the product within the excess flow area in the chart below Maintenance Turn off the power supply stop the fluid and check the safety before performing any maintenance There is a risk of unexpecte...

Страница 11: ...flow rate to zero completely If it is necessary to reduce the flow rate to zero completely install a stop valve etc separately Do not lift it by gripping the knob of the flow adjustment valve Hold the...

Страница 12: ...11 No PF OMN0010 J Model Indication and How to Order Metal piping...

Страница 13: ...12 No PF OMN0010 J Polyvinyl chloride piping...

Страница 14: ...10 4 pcs Lead wire with M8 connector ZS 40 A Lead wire length 3 m 2 brackets are necessary if using the type with flow rate adjustment valve Bracket cannot be mounted onto the 250 L min type Replaceme...

Страница 15: ...racket for mounting the product Temperature sensor Sensor for detecting the fluid temperature Flow adjustment valve Restricting valve to adjust the flow rate Flow adjustment knob Knob for adjusting th...

Страница 16: ...ices are generated is proportional to the fluid velocity therefore it is possible to calculate the fluid flow rate by measuring the Karman vortex frequency M Measured fluid The fluid s that the produc...

Страница 17: ...ta for operating pressure and proof pressure Mounting Never mount the product in a location where it will be used as a support Mount the product so that the fluid flows in the direction indicated by t...

Страница 18: ...nt valve attached fix using 8 mounting screws Bracket thickness is approx 1 5 mm Refer to the outline dimension drawing page 41 for mounting hole size Bracket mounting PF3W511 Mount the product with b...

Страница 19: ...g torque must be 0 5 to 0 7 Nm Refer to the outline dimension drawing page 41 for mounting hole dimensions The self tapping screws should not be re used Direct mounting PF3W511 521 Mount using the sel...

Страница 20: ...1 41 mm 11 4 54 mm 11 2 54 mm Tighten to the specified torque for piping The tightening torque for connection threads is shown in the table below Nominal thread size Tightening torque Rc NPT 3 8 22 to...

Страница 21: ...weight of the flexible hose and the fluid will be applied to the product Caution Vinyl chloride piping Mounting and joining of the vinyl chloride fitting union The vinyl chloride fitting union must be...

Страница 22: ...eakage generated after adjustment When fluid leakage is generated open and close the valve several times for re adjustment and confirm that there is no fluid leakage 3 Tighten the lock ring to fix the...

Страница 23: ...uch as a line noise filter and ferrite core between the switch mode power supply and the product or by using a series power supply instead of a switch mode power supply Pin No Description Wire colour...

Страница 24: ...utput is operating Green Flashes once PF3W5 1 Analogue 1 to 5 V type Without temperature sensor Flashes twice PF3W5 2 Analogue 4 to 20 mA type Without temperature sensor Flashes three times PF3W5 1T A...

Страница 25: ...wer cut or when the power has been unexpectedly removed The output condition also recovers to that before the power cut or de energizing but may change depending on the operating environment Therefore...

Страница 26: ...n matter has got stuck inside We recommend a filter with filtration of approx 40 mesh Remove foreign matter Piping is connected in the wrong direction Confirm whether the mounting direction of the pro...

Страница 27: ...tes or whether pulsation is generated due to the characteristics of the compressor or pump used as the pressure source Change to a pump that has less pulsation Install a tank to reduce the pressure fl...

Страница 28: ...uid temperature to within the rated temperature range Flow rate upper limit exceeded and Outside the temperature measurement range occur together POWER indicator Flashing Red FLOW indicator Red is ON...

Страница 29: ...er to graph of pressure loss Analogue output Response time 3 1 s Voltage output Output voltage 1 to 5 V Output impedance 1 k Current output Current output 4 to 20 mA Maximum load impedance 300 for 12...

Страница 30: ...250 VAC 5 If a reduced piping diameter or the piping layout cause a restriction it may not satisfy the specifications The form of the G thread including the major and minor diameter and pitch of the i...

Страница 31: ...ption 30 mA max Environment Enclosure IP65 Operating temperature range 0 to 50 oC No freezing and condensation Operating humidity range Operation Storage 35 to 85 R H No condensation Withstand voltage...

Страница 32: ...ilable available depending on the conditions The material and fluid compatibility check list provides reference values for reference only therefore we do not guarantee the application to our product 1...

Страница 33: ...32 No PF OMN0010 J Characteristics graph Measurable range of ethylene glycol aqueous solution Reference value...

Страница 34: ...33 No PF OMN0010 J Flow characteristics pressure loss PF3W504 PF3W520 PF3W540 PF3W511 Metal attachment PF3W521 Metal attachment...

Страница 35: ...34 No PF OMN0010 J PF3W511 Vinyl chloride piping PF3W521 Vinyl chloride piping...

Страница 36: ...35 No PF OMN0010 J Operating pressure and proof pressure PF3W504 520 540 PF3W504S 520S 540S PF3W511 Metal attachment PF3W521 Metal attachment PF3W511 521 Vinyl chloride piping...

Страница 37: ...piping length Fluid pressure has almost no effect The smaller the flow rate the less the product is affected by the straight piping length The straight piping length shall be 8 cm or longer in order...

Страница 38: ...37 No PF OMN0010 J PF3W521 Metal attachment...

Страница 39: ...PF OMN0010 J Vinyl chloride piping Fluid pressure has almost no effect The straight piping length shall be 11 cm or longer in order to maintain 3 F S of the specification PF3W511 521 Vinyl chloride p...

Страница 40: ...39 No PF OMN0010 J Flow characteristics of the flow rate adjustment valve PF3W504S PF3W520S PF3W540S...

Страница 41: ...mA 5 6 mA 20 mA PF3W521 12 14 A B C Voltage output 1 V 1 8 V 5 V Current output 4 mA 7 2 mA 20 mA PF3W521 U30 A B C Voltage output 1 V 1 48 V 5 V Current output 4 mA 5 92 mA 20 mA Sensor model Rated...

Страница 42: ...3W520 3 8 1 2 78 54 30 45 6 40 6 15 2 27 18 39 30 18 13 6 2 7 depth 12 PF3W540 1 2 3 4 98 71 38 53 6 48 6 19 2 32 28 49 35 28 16 8 2 7 depth 12 PF3W511 3 4 1 124 92 46 62 6 57 6 23 41 42 63 48 28 18 3...

Страница 43: ...N0010 J PF3W521 Basic type Symbol Piping port size A AA B DD E F G H J K L N P Model PF3W521 11 4 11 2 104 74 56 76 6 71 6 28 5 54 31 52 39 5 25 27 5 3 5 depth 14 G 11 4 108 76 33 54 41 5 G 11 2 112 7...

Страница 44: ...10 J PF3W504 520 540 511 521 With temperature sensor Temperature sensor Symbol A AA Model PF3W504 T 81 50 PF3W520 T 89 54 PF3W540 T 109 71 PF3W511 T 135 92 PF3W521 T 115 74 PF3W521 F12 T 119 76 PF3W52...

Страница 45: ...umber of rotations Model PF3W504S 104 50 63 6 Max 68 6 70 2 34 58 5 18 13 6 2 7 depth 10 19 6 turns PF3W520S 112 54 63 6 Max 68 6 74 2 34 62 5 18 13 6 2 7 depth 10 19 6 turns PF3W540S 142 71 75 25 Max...

Страница 46: ...40 With temperature sensor and flow adjustment valve Basic type and flow adjustment valve and temperature sensor Symbol A AA D K S Model PF3W504S T 115 50 81 2 69 5 67 5 PF3W520S T 123 54 85 2 73 5 71...

Страница 47: ...1 U30 Vinyl chloride piping Piping port A B D E F J K L N P Q 25 A 154 46 77 57 6 23 77 63 28 18 3 5 depth 14 32 32 A 146 56 91 71 6 28 5 73 60 5 25 27 5 3 5 depth 14 38 Piping port Bracket dimensions...

Страница 48: ...47 No PF OMN0010 J Dimensions of lead wire with M8 connector ZS 40 A...

Страница 49: ...terial of the piping port to brass Refer to page 11 for details of how to order Not applicable to the vinyl chloride piping type Not applicable to the flow rate adjustment valve mounted type Can be do...

Страница 50: ...veral places H Contents are added I Contents revised in several places March 2017 J Contents revised in several places July 2018 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax...

Отзывы: