-30-
No.PF
※※
-OMN0010-J
Specifications of body (Vinyl chloride piping)
Model
PF3W511
PF3W521
Applicable fluid
Water and ethylene glycol solution with a viscosity of 3 mPa
s(3 cP) or less
1
Detecting method
Karman vortex
Rated flow range
10 to 100 L/min
30 to 250 L/min
Fluid temperature
0 to 70
o
C (No freezing and condensation)
Accuracy
±3% F.S. max.
Repeatability
±2% F.S. max.
Temperature
characteristics
±5% F.S. max. (reference 25
o
C)
Operating pressure
range
2
Refer to graph of operating pressure and proof pressure
Proof pressure
2
Refer to graph of operating pressure and proof pressure
Pressure loss
Refer to graph of pressure loss
Analogue
output
Response
time
3
1 s
Voltage
output
Output voltage: 1 to 5 V, Output impedance: 1
kΩ
Current
output
Current output: 4 to 20 mA
Maximum load impedance: 300
Ω for 12 VDC, 600 Ω for 24 VDC
Indicator light
LED for power supply,
LED for flow rate indicator (Flashing speed changes depending on the flow rate.),
LED for other error display
Power supply voltage
12 to 24 VDC ±10%
Current consumption
30 mA max.
En
v
iro
n
m
e
n
t
Enclosure
IP65
Operating
temperature
range
0 to 50
o
C (No freezing and condensation)
Operating
humidity
range
Operation, Storage: 35 to 85% R.H. ( No condensation)
Withstand
voltage
1000 VAC, for 1 minute between the terminals and housing
Insulation
resistance
50 MΩ min. (with 500 VDC) between the terminals and housing
Standards and
regulations
CE marking, UL(CSA), RoHS
Wetted materials
PPS, FKM, CPVC
Non-grease type
Piping port size
4
25A union
30 A
Weight
Without lead
wire
270 g
325 g
With lead
wire
355 g
410 g
1: Please refer to the chart of measurement range of ethylene glycol aqueous solution on page
32
. Measurement is possible as long as
the fluid does not corrode the wetted parts, and viscosity is 3 mPa
s (3 cP) or less. Be aware that water leakage may happen due to
internal seal shrinkage or swelling depending on kinds of fluid. Refer to the "Applicable fluid list" on page
31
.
2: The operating pressure range and proof pressure vary depending on the fluid temperature. Refer to the chart on page
35
.
3: The response time is when the set value is 90% in relation to the step input.
4: If a reduced piping diameter or the piping layout cause a restriction, it may not satisfy the specifications.
Содержание PF3W5 Series
Страница 12: ...11 No PF OMN0010 J Model Indication and How to Order Metal piping...
Страница 13: ...12 No PF OMN0010 J Polyvinyl chloride piping...
Страница 33: ...32 No PF OMN0010 J Characteristics graph Measurable range of ethylene glycol aqueous solution Reference value...
Страница 35: ...34 No PF OMN0010 J PF3W511 Vinyl chloride piping PF3W521 Vinyl chloride piping...
Страница 38: ...37 No PF OMN0010 J PF3W521 Metal attachment...
Страница 40: ...39 No PF OMN0010 J Flow characteristics of the flow rate adjustment valve PF3W504S PF3W520S PF3W540S...
Страница 48: ...47 No PF OMN0010 J Dimensions of lead wire with M8 connector ZS 40 A...