-22-
No.PF
※※
-OMN0010-J
■
Wiring
Wiring of connector
Connections should only be made with the power supply turned off.
Use separate routes for the Flow sensor wiring and any power or high voltage wiring. Otherwise,
malfunction may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
Pin No.
Description
Wire colour
1
DC(+)
Brown
2
N.C. / T em. analogue output (1 to 5 V)
White
3
DC(-)
Blue
4
Flow analogue output (1 to 5 V, 4 to 20 mA)
Black
: When using the lead wire with M8 connector included with the PF3W5 series.
Tighten the connector by hand.
Examples of Internal Circuit and Wiring
1 to 5 V / 4 to 20 mA output type
PF3W5
-
-1/2
With temperature sensor 1 to 5 V output type
PF3W5
-
-1T
Analogue output 1 to 5 V
Output impedance: 1 k
Analogue output 4 to 20 mA
Maximum load impedance
Power supply voltage 12 V: 300
Power supply voltage 24 V: 600
Analogue output 1 to 5 V
Output impedance: 1 k
Содержание PF3W5 Series
Страница 12: ...11 No PF OMN0010 J Model Indication and How to Order Metal piping...
Страница 13: ...12 No PF OMN0010 J Polyvinyl chloride piping...
Страница 33: ...32 No PF OMN0010 J Characteristics graph Measurable range of ethylene glycol aqueous solution Reference value...
Страница 35: ...34 No PF OMN0010 J PF3W511 Vinyl chloride piping PF3W521 Vinyl chloride piping...
Страница 38: ...37 No PF OMN0010 J PF3W521 Metal attachment...
Страница 40: ...39 No PF OMN0010 J Flow characteristics of the flow rate adjustment valve PF3W504S PF3W520S PF3W540S...
Страница 48: ...47 No PF OMN0010 J Dimensions of lead wire with M8 connector ZS 40 A...