11. Transition wiring of ionizer

For transition wiring of ionizers, use a transition wiring cable for connection 
between ionizers. Use a power supply cable for connection between ionizer 
and power supply or external equipment. (Transition wiring is not possible with 
the IZS40.) The number of ionizers that may be connected using transition 
wiring varies depending on the power supply cable; the length of the transition 
wiring cable; the use of external sensor(s) and/or models. Refer to the table 
shown below “Connectable number of ionizers with transition wiring.”
The IZS41 and IZS42 can be connected in the same transition wiring, but 
mixed wiring of the NPN and PNP I/O specifications is not possible.
Please contact SMC when connecting conditions other than specified in the 
table below are applied.

It is recommended that the power supply used to operate the ionizers 
have a current capacity twice that of the total current consumption of 
the ionizers to be used. Power supply voltage should be from 24 to 
26.4 VDC.
AC adapter must not be used when ionizer is used in a transition wiring.
When ionizers are connected with transition wiring, the same input 
signal serves as input to all the ionizers. When a signal is output from at 
least one ionizer in the connection, the signal will be output from the 
power supply cable.
Connect the power supply cable to the “POWER” connector of the 1st 
ionizer, and connect the “LINK” connector of the 1st ionizer to the 
“POWER” connector of the 2nd ionizer with a transition wiring cable. 
Follow the same procedure to connect subsequent ionizer(s) and after 
with transition wiring cables.

2. Make sure to confirm the effect of static neutraliza-

tion after installation.

The effects vary depending on the ambient conditions, operating  
conditions, etc. After installation, verify the effects of static neutralization.

3. When installing the IZS41 or IZS42 in proximity with 

an ionizer which operates in DC mode, they should 
be positioned at least 2 meters away from each other.

When using the IZS41 or IZS42 near the ionizer in DC mode, 
keep clearance of at least 2 m between them.
The offset voltage may not be adjusted by the built-in sensor 
due to the ions discharged from the DC mode ionizer.

Wiring / Piping

Warning

1. Before wiring, ensure that the power supply capacity is 

enough and that the voltage is within the specification.

2. To maintain product performance, the power supply shall be 

UL listed Class 2 certified by National Electric Code (NEC) or 

evaluated as a limited power source provided by UL60950.

3. Ground the F.G. wire with 100 

 or less according to the 

instructions in this catalog. An incomplete ground or no grounding 

not only prevents the performance of the product from being 

maintained, but may also cause failure or damage of the product, 

or electric shock to the human body.

4.

 Be sure to turn off the power supply before wiring 

(including insertion and removal of the connector).

5. To connect a feedback sensor or auto balance sensor 

to the ionizer, use the cable included with the sensor. 

Do not disassemble or modify the ionizer.

6. Ensure the safety of wiring and surrounding condi-

tions before supplying power.

7. Do not connect or disconnect the connectors (in-

cluding power source) while the power is supplied. 

Otherwise, the ionizer may malfunction.

8. If the ionizer wiring and high power lines are routed 

together, this product may malfunction due to noise. 

Therefore, use a separate wiring route for this product.

9. Confirm that the wiring is correct before operation. Incor-

rect wiring will lead to product damage or malfunction.

10. Flush the piping before use. Before piping this 

product, exercise caution to prevent particles, water 

drops, or oil contents from entering the piping.

Bar

length

symbol

  340
  400
  460
  580
  640
  820
1120
1300
1600
1900
2320
2500

Connectable number of ionizers (IZS41) with transition wiring (without external sensor)

Bar

length

symbol

  340
  400
  460
  580
  640
  820
1120
1300
1600
1900
2320
2500

Connectable number of ionizers (IZS42) with transition wiring (without external sensor)

8 units

4 units

6 units

5 units

5 units

4 units

3 units

7 units

7 units

8 units

7 units 6 units

6 units

7 units

5 units

3 units

4 units

4 units

5 units

3 units

1 2 3 4 5 6 7 8 9 10

Transition wiring cable length (same cable length) [m]

Power supply cable length: 3 m 

1 2 3 4 5 6 7 8 9 10

Transition wiring cable length (same cable length) [m]

Power supply cable length: 10 m 

1 2 3 4 5 6 7 8 9 10

Transition wiring cable length (same cable length) [m]

Power supply cable length: 3 m 

1 2 3 4 5 6 7 8 9 10

Transition wiring cable length (same cable length) [m]

Power supply cable length: 10 m 

IZS40/41/42 

Series

Specific Product Precautions 2

Be sure to read this before handling the products.
Refer to the back cover for safety instructions.

28

Содержание IZS40

Страница 1: ...r ON Standard Type IZS40 Series 1 IZS42 installation height 300 mm 2 Conditions With feedback sensor Discharge time from 1000 V to 100 V Object to be neutralized Charged plate 150 mm x 150 mm Capacita...

Страница 2: ...neration frequency 30 Hz Supply pressure 0 1 MPa High speed static neutralization cartridge For the static neutralization of glass substrates For the static neutralization of electric substrates Dual...

Страница 3: ...ck Sensor Type IZS41Series Feedback sensor Detects the polarity of the object to be neutralized and measures the charged voltage Stop Ion emission waveform Operating mode Energy saving mode Continuous...

Страница 4: ...maintained at a constant value This is achieved by monitoring the ions emitted from the ionizer using the ground line and adjusting the and ion supply rates Adjustment and maintenance labor can be red...

Страница 5: ...d 30 0 30 Offset voltage V Time Effect of auto balance sensor Image Sensor not connected Sensor connected Continuously controls offset voltage around workpieces Tungsten Single crystal silicon for sil...

Страница 6: ...cover For increased cartridge drop prevention When attached to the body From the 7th ionizer To the 3rd ionizer Transition wiring cable To POWER for the 2nd ionizer 8th ionizer 2nd ionizer 1st ionize...

Страница 7: ...ter cartridge type Remote controller AC adapter Drop prevention cover Cleaning kit Series AC DC IZS40 AC Sensing AC DC IZS41 Dual AC IZS42 Series IZS40 IZS41 IZS42 Accessories sold separately per seri...

Страница 8: ...ion of finished goods For the static neutralization during wafer transfer Prevents breakage due to discharge between wafers and hands For the static neutralization of packing films Prevents the filled...

Страница 9: ...p 14 How to Order p 15 Made to Order p 16 Specifications p 17 Construction p 17 Accessories for Individual Parts p 18 Accessories Sold Separately p 19 Wiring IZS40 p 20 Connection Circuit IZS40 p 20...

Страница 10: ...0 0 50 150 100 200 Discharge time s Installation distance mm 10 8 6 4 2 0 0 500 1500 1000 2000 Discharge time s Installation distance mm 0 1 MPa 0 5 MPa 0 2 MPa 0 3 MPa 0 4 MPa 10 8 6 4 2 0 0 500 1500...

Страница 11: ...er horizontal direction mm 0 50 100 150 200 250 300 150 100 50 0 50 100 150 150 100 50 0 50 100 150 5 s 2 s 1 s 0 5 s Installation distance in height from ionizer to workpiece Charged object location...

Страница 12: ...0 50 0 50 100 150 200 250 Installation distance in height from ionizer to workpiece Charged object location mm Ionizer front back direction mm 5 s 2 s 1 s 0 5 s 0 50 100 150 200 250 300 150 100 50 0 5...

Страница 13: ...00 250 300 150 100 50 0 50 100 150 150 100 50 0 50 100 150 Installation distance in height from ionizer to workpiece Charged object location mm Ionizer horizontal direction mm 5 s 2 s 1 s 0 5 s 3 Ener...

Страница 14: ...al amplitude V Installation distance mm 0 50 25 100 75 150 125 175 200 0 500 1000 1500 2000 Potential amplitude V Installation distance mm 0 1 Hz 30 Hz ePotential Amplitude High speed static neutraliz...

Страница 15: ...ure measurement 10 mm Pressure measurement Air supply measurement 10 mm 10 mm 10 mm Pressure measurement 10 mm Air supply measurement High speed static neutralization cartridge Energy saving high effi...

Страница 16: ...ion cartridge Tungsten C Silicon J Energy saving static neutralization cartridge Tungsten K Silicon V Energy saving high efficiency cartridge Tungsten S Silicon e Bar length Symbol Bar length mm Symbo...

Страница 17: ...revention cover available as an option 520 1000 1420 1780 2140 700 1060 1480 1840 2200 760 1180 1540 1960 2260 880 1240 1660 2020 2380 940 1360 1720 2080 2440 Symbol Description Specifications X10 Non...

Страница 18: ...voltageiondischargedetection Iondischargestopsduringdetection Offset voltage control with the built in sensor maintenance detection incorrect high voltage ion discharge detection stops discharge durin...

Страница 19: ...1 m increments from 1 m to 20 m 11 m or longer power cables are not CE Marking compliant Use standard power supply cables for 3 m and 10 m lengths Made to Order Power supply cable full length IZS CP...

Страница 20: ...tandard model no For IZS40 For IZS41 42 How to Order Model with Made to order transition wiring cable Available in 1 m increments from 1 m to 20 m 11 m or longer power cables are not CE Marking compli...

Страница 21: ...e applicable wire size 2 Insert the cable which was cut into the back of the connector 3 Confirm that the cable is inserted into the back of the connector and press part A with your finger to hold ten...

Страница 22: ...ion discharge NPN specification Stops ion discharge by connecting to 0 V Starts discharging ion when disconnected PNP specification Stops ion discharge by connecting to 24 VDC Starts discharging ion w...

Страница 23: ...detection signal Purple Error signal Internal circuit Shield Ground with a ground resistance of 100 or less Internal circuit 24 V Power supply 24 VDC 0 V 0 V 0 V DC DC F G PLC INPUT INPUT Isolation c...

Страница 24: ...4 5 30 2 x 5 4 18 105 33 Cross sectional view A A Part no n L mm IZS40 340 5 340 IZS40 400 6 400 IZS40 460 7 460 IZS40 580 9 580 IZS40 640 10 640 IZS40 820 13 820 IZS40 1120 18 1120 IZS40 1300 21 1300...

Страница 25: ...tional view A A A A 36 55 35 22 4 5 30 18 2 x 5 4 105 33 Part no n L mm IZS4 340 5 340 IZS4 400 6 400 IZS4 460 7 460 IZS4 580 9 580 IZS4 640 10 640 IZS4 820 13 820 IZS4 1120 18 1120 IZS4 1300 21 1300...

Страница 26: ...4 Amplifier 3500 23 4 8 69 78 11 13 0 5 0 5 6 5 8 8 7 8 10 2 10 2 13 14 8 8 Detection hole 61 7 5 10 5 2 x R 3 3 10 60 7 7 1 6 2 x 3 4 20 98 95 0 2 0 2 Head 1500 4 8 6 6 2 x 3 4 Amplifier 69 78 3500...

Страница 27: ...Nominal cross section 0 2 mm2 Outside diameter 0 66 mm Insulator Outside diameter 1 0 mm Sheath Material Lead free PVC Outside diameter 3 8 mm No of cable wires Size 10 cores AWG20 4 cores AWG28 6 cor...

Страница 28: ...ting brackets may break Also if under tightened with a low torque the connection may loosen Refer to the operation manual for details 6 Do not touch the emitter directly with fingers or metallic tools...

Страница 29: ...scharged from the DC mode ionizer Wiring Piping Warning 1 Before wiring ensure that the power supply capacity is enough and that the voltage is within the specification 2 To maintain product performan...

Страница 30: ...o ISO 8573 1 2010 is recommended for operation 5 Ionizer feedback sensor auto balance sensor remote controller and AC adapter are not resistant to lightening surge 6 Effects on implantable medical dev...

Страница 31: ...the ends of the bar Handling the product by holding either end of the bar may cause damage to the product 3 When mounting dismounting the cable use your finger to pinch the claw of the plug then attac...

Страница 32: ...nction 4 Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions 1 Conditions and environments outside of the given spe...

Отзывы: