background image

r

t

w

q

e

w

r

t

q

e

y

u

i

o

Specifications

Number of Emitter Cartridges/Bar Weight

External Sensor

Construction

*

1  When the air purge is performed between a charged object and an ionizer at a distance of 300 mm

AC Adapter (Sold Separately)

Remote Controller (Sold Separately)

IZS41, 42 series

IZS40 series

*

1   Varies depending on the operating 

conditions and environment

*

2  Batteries are not supplied.

*

   Refer to the operation manual for 

handling of the remote controller.

Ionizer model

IZS40

IZS41-



 

(NPN)

IZS41-



P 

(PNP)

IZS42-



 

(NPN)

IZS42-



P 

(PNP)

Ion generation method

Corona discharge type

Method of applying voltage

AC, DC

AC, Sensing AC, DC

Dual AC

Applied voltage

±

7000 V

±

6000 V

Offset voltage

*

1

Within 

±

30 V

Air purge

Fluid

Air (Clean dry air)

Operating pressure

0.5 MPa or less

Proof pressure

0.7 MPa

Connecting tube size

Metric size: ø4, ø6, ø8, ø10   Inch size: ø3/16", ø1/4", ø5/16", ø3/8"

Current consumption

330 mA or less

440 mA or less (Sensing AC, Automatic operation/

Manual operation: 480 mA or less)

700 mA or less

(Automatic operation/Manual operation: 740 mA or less)

Power supply voltage

21.6 to 26.4 VDC (Within 24 VDC 

±

10%)

Power supply voltage in a transition wiring

24 VDC to 26.4 VDC

Input signal

Discharge stop signal

Connected to 0 V
Voltage range: 5 VDC or less
Current consumption: 5 mA or less

Connected to +24 V
Voltage range: 19 VDC to power supply voltage
Current consumption: 5 mA or less

Connected to 0 V
Voltage range: 5 VDC or less
Current consumption: 5 mA or less

Connected to +24 V
Voltage range: 19 VDC to power supply voltage
Current consumption: 5 mA or less

Maintenance detection 

signal

Output signal

Maintenance detection 

signal

Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Max. applied voltage: 26.4 VDC

Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)

Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Max. applied voltage: 26.4 VDC

Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)

Error signal

Function

Incorrect high voltage ion discharge detection

(Ion discharge stops during detection)

Offset voltage control with the built-in sensor, maintenance detection, incorrect high voltage ion discharge detection

(stops discharge during detection), ion discharge stop input, transition wiring, remote controller (sold separately), external sensor connection

Effective static neutralization 

distance

50 to 2000 mm

50 to 2000 mm (Sensing AC mode: 200 to 2000 mm,

Manual operation/Automatic operation: 100 to 2000 mm)

50 to 2000 mm

(Manual operation/Automatic operation: 100 to 2000 mm)

Ambient and fluid temperatures

0 to 40

°

C

Ambient humidity

35 to 80% RH (No condensation)

Material

Body cover: ABS, Emitter cartridge: PBT, Emitter: Tungsten, Single crystal silicon

Impact resistance

100 m/s

2

Standards/Directive

CE (EMC Directive: 2004/108/EC)

Bar length symbol

340

400

460

  580

  640

  820

1120

1300

1600

1900

2320

2500

Number of emitter cartridges

    5

    6

    7

      9

    10

    13

    18

    21

    26

    31

    38

    41

Weight [g]

IZS40

590

640

690

  790

  830

  980

1220

1360

1600

1840

2170

2320

IZS41

740

790

840

  940

  980

1130

1370

1510

1750

1990

2320

2470

IZS42

860

910

960

1060

1100

1250

1490

1630

1870

2110

2440

2590

Sensor model

IZS31-DF

 (Feedback sensor)

IZS31-DG

 (Auto balance sensor) [High accuracy type]

Ambient temperature

0 to 50

°

C

Ambient humidity

35 to 80% RH (No condensation)

Case material

ABS

ABS, Stainless steel

Impact resistance

100 m/s

2

Weight

200 g (Including cable weight)

220 g (Including cable weight)

Installation distance

10 to 50 mm (Recommended)

Standards/Directive

CE, UL, CSA

Model

IZF10-CG

, IZS41-CG

Input voltage

100 VAC to 240 VAC, 50/60 Hz

Output current

1 A

Ambient temperature

0 to 40

°

C

Ambient humidity 35 to 65% RH (No condensation)
Weight

220 g

Standards/Directive

CE, UL, CSA

Model

IZS41-RC

Type

Infrared ray type

Transmission capacity

5 m

*

1

Power supply

2 AAA sized batteries (sold separately)

*

2

Ambient temperature

0 to 45

°

C

Ambient humidity 35 to 80% RH (No condensation)
Weight

33 g (Excluding dry cell batteries)

Standards/Directive

CE

No.

Description

1 Ionizer
2 Emitter cartridge
3 One-touch fitting
4 End bracket
5 Intermediate bracket
6 Feedback sensor
7 Auto balance sensor [High accuracy type]
8 Power supply cable (for IZS40)
9 Power supply cable (for IZS41, 42)

17

IZS40/41/42 

Series

A

Содержание IZS40

Страница 1: ...r ON Standard Type IZS40 Series 1 IZS42 installation height 300 mm 2 Conditions With feedback sensor Discharge time from 1000 V to 100 V Object to be neutralized Charged plate 150 mm x 150 mm Capacita...

Страница 2: ...neration frequency 30 Hz Supply pressure 0 1 MPa High speed static neutralization cartridge For the static neutralization of glass substrates For the static neutralization of electric substrates Dual...

Страница 3: ...ck Sensor Type IZS41Series Feedback sensor Detects the polarity of the object to be neutralized and measures the charged voltage Stop Ion emission waveform Operating mode Energy saving mode Continuous...

Страница 4: ...maintained at a constant value This is achieved by monitoring the ions emitted from the ionizer using the ground line and adjusting the and ion supply rates Adjustment and maintenance labor can be red...

Страница 5: ...d 30 0 30 Offset voltage V Time Effect of auto balance sensor Image Sensor not connected Sensor connected Continuously controls offset voltage around workpieces Tungsten Single crystal silicon for sil...

Страница 6: ...cover For increased cartridge drop prevention When attached to the body From the 7th ionizer To the 3rd ionizer Transition wiring cable To POWER for the 2nd ionizer 8th ionizer 2nd ionizer 1st ionize...

Страница 7: ...ter cartridge type Remote controller AC adapter Drop prevention cover Cleaning kit Series AC DC IZS40 AC Sensing AC DC IZS41 Dual AC IZS42 Series IZS40 IZS41 IZS42 Accessories sold separately per seri...

Страница 8: ...ion of finished goods For the static neutralization during wafer transfer Prevents breakage due to discharge between wafers and hands For the static neutralization of packing films Prevents the filled...

Страница 9: ...p 14 How to Order p 15 Made to Order p 16 Specifications p 17 Construction p 17 Accessories for Individual Parts p 18 Accessories Sold Separately p 19 Wiring IZS40 p 20 Connection Circuit IZS40 p 20...

Страница 10: ...0 0 50 150 100 200 Discharge time s Installation distance mm 10 8 6 4 2 0 0 500 1500 1000 2000 Discharge time s Installation distance mm 0 1 MPa 0 5 MPa 0 2 MPa 0 3 MPa 0 4 MPa 10 8 6 4 2 0 0 500 1500...

Страница 11: ...er horizontal direction mm 0 50 100 150 200 250 300 150 100 50 0 50 100 150 150 100 50 0 50 100 150 5 s 2 s 1 s 0 5 s Installation distance in height from ionizer to workpiece Charged object location...

Страница 12: ...0 50 0 50 100 150 200 250 Installation distance in height from ionizer to workpiece Charged object location mm Ionizer front back direction mm 5 s 2 s 1 s 0 5 s 0 50 100 150 200 250 300 150 100 50 0 5...

Страница 13: ...00 250 300 150 100 50 0 50 100 150 150 100 50 0 50 100 150 Installation distance in height from ionizer to workpiece Charged object location mm Ionizer horizontal direction mm 5 s 2 s 1 s 0 5 s 3 Ener...

Страница 14: ...al amplitude V Installation distance mm 0 50 25 100 75 150 125 175 200 0 500 1000 1500 2000 Potential amplitude V Installation distance mm 0 1 Hz 30 Hz ePotential Amplitude High speed static neutraliz...

Страница 15: ...ure measurement 10 mm Pressure measurement Air supply measurement 10 mm 10 mm 10 mm Pressure measurement 10 mm Air supply measurement High speed static neutralization cartridge Energy saving high effi...

Страница 16: ...ion cartridge Tungsten C Silicon J Energy saving static neutralization cartridge Tungsten K Silicon V Energy saving high efficiency cartridge Tungsten S Silicon e Bar length Symbol Bar length mm Symbo...

Страница 17: ...revention cover available as an option 520 1000 1420 1780 2140 700 1060 1480 1840 2200 760 1180 1540 1960 2260 880 1240 1660 2020 2380 940 1360 1720 2080 2440 Symbol Description Specifications X10 Non...

Страница 18: ...voltageiondischargedetection Iondischargestopsduringdetection Offset voltage control with the built in sensor maintenance detection incorrect high voltage ion discharge detection stops discharge durin...

Страница 19: ...1 m increments from 1 m to 20 m 11 m or longer power cables are not CE Marking compliant Use standard power supply cables for 3 m and 10 m lengths Made to Order Power supply cable full length IZS CP...

Страница 20: ...tandard model no For IZS40 For IZS41 42 How to Order Model with Made to order transition wiring cable Available in 1 m increments from 1 m to 20 m 11 m or longer power cables are not CE Marking compli...

Страница 21: ...e applicable wire size 2 Insert the cable which was cut into the back of the connector 3 Confirm that the cable is inserted into the back of the connector and press part A with your finger to hold ten...

Страница 22: ...ion discharge NPN specification Stops ion discharge by connecting to 0 V Starts discharging ion when disconnected PNP specification Stops ion discharge by connecting to 24 VDC Starts discharging ion w...

Страница 23: ...detection signal Purple Error signal Internal circuit Shield Ground with a ground resistance of 100 or less Internal circuit 24 V Power supply 24 VDC 0 V 0 V 0 V DC DC F G PLC INPUT INPUT Isolation c...

Страница 24: ...4 5 30 2 x 5 4 18 105 33 Cross sectional view A A Part no n L mm IZS40 340 5 340 IZS40 400 6 400 IZS40 460 7 460 IZS40 580 9 580 IZS40 640 10 640 IZS40 820 13 820 IZS40 1120 18 1120 IZS40 1300 21 1300...

Страница 25: ...tional view A A A A 36 55 35 22 4 5 30 18 2 x 5 4 105 33 Part no n L mm IZS4 340 5 340 IZS4 400 6 400 IZS4 460 7 460 IZS4 580 9 580 IZS4 640 10 640 IZS4 820 13 820 IZS4 1120 18 1120 IZS4 1300 21 1300...

Страница 26: ...4 Amplifier 3500 23 4 8 69 78 11 13 0 5 0 5 6 5 8 8 7 8 10 2 10 2 13 14 8 8 Detection hole 61 7 5 10 5 2 x R 3 3 10 60 7 7 1 6 2 x 3 4 20 98 95 0 2 0 2 Head 1500 4 8 6 6 2 x 3 4 Amplifier 69 78 3500...

Страница 27: ...Nominal cross section 0 2 mm2 Outside diameter 0 66 mm Insulator Outside diameter 1 0 mm Sheath Material Lead free PVC Outside diameter 3 8 mm No of cable wires Size 10 cores AWG20 4 cores AWG28 6 cor...

Страница 28: ...ting brackets may break Also if under tightened with a low torque the connection may loosen Refer to the operation manual for details 6 Do not touch the emitter directly with fingers or metallic tools...

Страница 29: ...scharged from the DC mode ionizer Wiring Piping Warning 1 Before wiring ensure that the power supply capacity is enough and that the voltage is within the specification 2 To maintain product performan...

Страница 30: ...o ISO 8573 1 2010 is recommended for operation 5 Ionizer feedback sensor auto balance sensor remote controller and AC adapter are not resistant to lightening surge 6 Effects on implantable medical dev...

Страница 31: ...the ends of the bar Handling the product by holding either end of the bar may cause damage to the product 3 When mounting dismounting the cable use your finger to pinch the claw of the plug then attac...

Страница 32: ...nction 4 Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions 1 Conditions and environments outside of the given spe...

Отзывы:

Похожие инструкции для IZS40