Specifications
Number of Emitter Cartridges/Bar Weight
External Sensor
Construction
*
1 When the air purge is performed between a charged object and an ionizer at a distance of 300 mm
AC Adapter (Sold Separately)
Remote Controller (Sold Separately)
IZS41, 42 series
IZS40 series
*
1 Varies depending on the operating
conditions and environment
*
2 Batteries are not supplied.
*
Refer to the operation manual for
handling of the remote controller.
Ionizer model
IZS40
IZS41-
(NPN)
IZS41-
P
(PNP)
IZS42-
(NPN)
IZS42-
P
(PNP)
Ion generation method
Corona discharge type
Method of applying voltage
AC, DC
AC, Sensing AC, DC
Dual AC
Applied voltage
±
7000 V
±
6000 V
Offset voltage
*
1
Within
±
30 V
Air purge
Fluid
Air (Clean dry air)
Operating pressure
0.5 MPa or less
Proof pressure
0.7 MPa
Connecting tube size
Metric size: ø4, ø6, ø8, ø10 Inch size: ø3/16", ø1/4", ø5/16", ø3/8"
Current consumption
330 mA or less
440 mA or less (Sensing AC, Automatic operation/
Manual operation: 480 mA or less)
700 mA or less
(Automatic operation/Manual operation: 740 mA or less)
Power supply voltage
21.6 to 26.4 VDC (Within 24 VDC
±
10%)
Power supply voltage in a transition wiring
—
24 VDC to 26.4 VDC
Input signal
Discharge stop signal
—
Connected to 0 V
Voltage range: 5 VDC or less
Current consumption: 5 mA or less
Connected to +24 V
Voltage range: 19 VDC to power supply voltage
Current consumption: 5 mA or less
Connected to 0 V
Voltage range: 5 VDC or less
Current consumption: 5 mA or less
Connected to +24 V
Voltage range: 19 VDC to power supply voltage
Current consumption: 5 mA or less
Maintenance detection
signal
Output signal
Maintenance detection
signal
—
Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Max. applied voltage: 26.4 VDC
Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Max. applied voltage: 26.4 VDC
Max. load current: 100 mA
Residual voltage: 1 V or less
(Load current at 100 mA)
Error signal
Function
Incorrect high voltage ion discharge detection
(Ion discharge stops during detection)
Offset voltage control with the built-in sensor, maintenance detection, incorrect high voltage ion discharge detection
(stops discharge during detection), ion discharge stop input, transition wiring, remote controller (sold separately), external sensor connection
Effective static neutralization
distance
50 to 2000 mm
50 to 2000 mm (Sensing AC mode: 200 to 2000 mm,
Manual operation/Automatic operation: 100 to 2000 mm)
50 to 2000 mm
(Manual operation/Automatic operation: 100 to 2000 mm)
Ambient and fluid temperatures
0 to 40
°
C
Ambient humidity
35 to 80% RH (No condensation)
Material
Body cover: ABS, Emitter cartridge: PBT, Emitter: Tungsten, Single crystal silicon
Impact resistance
100 m/s
2
Standards/Directive
CE (EMC Directive: 2004/108/EC)
Bar length symbol
340
400
460
580
640
820
1120
1300
1600
1900
2320
2500
Number of emitter cartridges
5
6
7
9
10
13
18
21
26
31
38
41
Weight [g]
IZS40
590
640
690
790
830
980
1220
1360
1600
1840
2170
2320
IZS41
740
790
840
940
980
1130
1370
1510
1750
1990
2320
2470
IZS42
860
910
960
1060
1100
1250
1490
1630
1870
2110
2440
2590
Sensor model
IZS31-DF
(Feedback sensor)
IZS31-DG
(Auto balance sensor) [High accuracy type]
Ambient temperature
0 to 50
°
C
Ambient humidity
35 to 80% RH (No condensation)
Case material
ABS
ABS, Stainless steel
Impact resistance
100 m/s
2
Weight
200 g (Including cable weight)
220 g (Including cable weight)
Installation distance
10 to 50 mm (Recommended)
—
Standards/Directive
CE, UL, CSA
Model
IZF10-CG
, IZS41-CG
Input voltage
100 VAC to 240 VAC, 50/60 Hz
Output current
1 A
Ambient temperature
0 to 40
°
C
Ambient humidity 35 to 65% RH (No condensation)
Weight
220 g
Standards/Directive
CE, UL, CSA
Model
IZS41-RC
Type
Infrared ray type
Transmission capacity
5 m
*
1
Power supply
2 AAA sized batteries (sold separately)
*
2
Ambient temperature
0 to 45
°
C
Ambient humidity 35 to 80% RH (No condensation)
Weight
33 g (Excluding dry cell batteries)
Standards/Directive
CE
No.
Description
1 Ionizer
2 Emitter cartridge
3 One-touch fitting
4 End bracket
5 Intermediate bracket
6 Feedback sensor
7 Auto balance sensor [High accuracy type]
8 Power supply cable (for IZS40)
9 Power supply cable (for IZS41, 42)
17
IZS40/41/42
Series
A