High precision and high resolution

Compound pressure

Repeatability   

0.2 %F.S.   

1digit or less

Variety of 

functions

Variations

Anti-chattering function

Auto shift function

Auto preset function

Key lock function

Peak and bottom display 

function

Zero out function

Automatic pressure setting is possible.
Saves time for setting operation.

Special fitting types are used in semiconductor 
production equipment (metal gasket seal fittings)

Selectable response times: 2.5ms (default), 24ms,

192ms, 768ms or less

Leak rate: 1 x  10

-10

Pa. m

3

/s

Confirmation of atmospheric pressure of load lock

ZSE/ ISE60(F)-A2

ZSE/ ISE60(F)-B2

1/2000 ( 0.1kPa)

Positive pressure

1/1000 ( 0.001MPa)

Series ZSE60F/ ISE60 

URJ 1 / 4

TSJ 1 / 4

Model

Standard thread type

Special fittings for the semiconductor industry

(metal gasket seal fittings)

Port size

Rated pressure range

Output

Switch output

Analog output

Leak rate

1 x 1 0

-5

Pa . m

3

/ s

ZSE50F

ISE50

ZSE60F

ISE60

outputs 

NPN or PNP

100kPa 

-100kPa 

1MPa 

100kPa 

-100kPa 

1MPa 

1 x  1 0

-1 0

Pa

m

3

/ s

Output voltage 

1 to 5V

R 1/ 4

NPT 1/4

G 1/ 4 (with M 5 male thread)

URJ 1 /4

TSJ  1 / 4

Prevents erroneous operation due to sud-
den fluctuations in primary pressure, by all-
owing the response time to be changed.

Pressure detection is not affected by 
fluctuations in primary pressure.

Approved

Features 2

ZSE/ISE  4/21/02 1:15 PM  Page 3

Содержание ISE50

Страница 1: ...tch Applicable for pressure detection with a wide range of fluids by using a stainless steel diaphragm F ISE ZSE High Precision Digital Pressure Switch For General Fluids 50 60 50 60 Series CAT ES100...

Страница 2: ...l diaphragm Extremely low leakage To confirm absorption of work piece with water on the surface e g wet LCD glass plate To measure hydraulic pressure The stainless steel diaphragm prevents direct cont...

Страница 3: ...of load lock ZSE ISE60 F A2 ZSE ISE60 F B2 1 2000 0 1kPa Positive pressure 1 1000 0 001MPa Series ZSE60F ISE60 URJ 1 4 TSJ 1 4 Model Standard thread type Special fittings for the semiconductor industr...

Страница 4: ...s NPN open collector 2 output Analog output NPN open collector 2 output Auto shift input PNP open collector 2 output Analog output PNP open collector 2 output Auto shift input 22 30 62 70 Option Brack...

Страница 5: ...e Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Vibration resistance Shock resistance ZSE50F Compound pressure 100 to 100kPa 100 to 100kPa 500kPa 0 1 0 001 0...

Страница 6: ...OUT2 OFF ON OFF ON OFF ON OFF ON Hysteresis mode Window comparator mode Hysteresis mode Window comparator mode P_1 Large pressure and vacuum pressure Large pressure and vacuum pressure Large pressure...

Страница 7: ...output 1k 12VDC to 24VDC 12VDC to 24VDC 12VDC to 24VDC 12VDC to 24VDC Main circuit Main circuit Main circuit Main circuit Load Load 6 8K 1 2K Brown DC Blue DC Black OUT 1 White OUT 2 Gray Auto shift i...

Страница 8: ...d on the EEPROM When auto shift is used When the primary pressure changes set the auto shift function to Lo The pressure value at this point will be saved as the reference value to correct the pressur...

Страница 9: ...sed the exce ss current turn the power supply back on Bring the pressure back to atmosp heric pressure and try using the zero out function Reduce Increase supply pressure to within the regulating pres...

Страница 10: ...6 4 18 35 3 5 30 8 45 Piping port R NPT 1 4 20 20 2 M3 x 0 5 depth 4 Piping port M5 x 0 8 depth 5 30 2 6 7 1 2 4 15 2 30 2 5 10 7 7 8 Piping port G Piping port 8 45 25 1 14 5 22 10 1 12 4 G 1 4 Serie...

Страница 11: ...utting dimensions for panel mounting Front protection cover 4 5 20 20 45 15 11 5 6 5 4 5 20 40 30 55 1 6 ZS 24 A Bracket A View A A 41 5 41 5 35 45 15 11 5 4 2 4 5 7 2 7 5 22 20 20 40 30 55 1 6 ZS 24...

Страница 12: ...en collector 2 output Analog output PNP open collector 2 output Auto shift input 22 30 62 70 Option Bracket A Bracket D Panel mount Panel mount Front protection cover Part no ZS 24 A ZS 24 D ZS 24 E Z...

Страница 13: ...to 100kPa 500kPa 0 1 0 001 0 001 0 02 1 0 1 ISE60 Positive pressure 0 000 to 1 000MPa 0 100 to 1 000MPa 1 5MPa 0 001 0 01 0 01 0 1 Possible set range 100 0 to 100 0kPa 1 000 to 1 000MPa Regulating pr...

Страница 14: ...0 3 5 18 35 6 4 27 7 Piping port URJ 1 4 2 6 7 1 2 4 30 2 5 10 7 7 8 15 2 The following items are identical with those of series ZSE50F ISE50 Item Output type Example of internal circuit and wiring Au...

Страница 15: ...thickness of the panel is to 3 2mm Cutting dimensions for panel mounting 41 5 1 6 55 30 40 20 20 A Bracket A ZS 24 A 4 5 20 4 5 6 5 11 5 15 45 View A 41 5 15 11 5 4 2 4 5 7 2 7 5 22 45 View A 20 20 40...

Страница 16: ...sure and operates switch Normal operation Value clear Manual fine adjustment Peak hold Key lock Bottom hold Unit conversion P 14 P 16 P 14 P 15 Set Output mode Res ponse time and Auto Manual mode The...

Страница 17: ...calibration SET Select the manual setting mode as the initial setting mode Press the SET button and hold it unit P_1 or n_1 appears on the display button Increases the set point value button Decrease...

Страница 18: ...neously to skip to RP2 Repeat vacuum and break several times while AIL is displayed The optimum set point value is deter mined automatically Change the vacuum nozzle or other conditions of the work pi...

Страница 19: ...tion returns to the measurement mode Press the SET button at least 2 seconds Release it when the display turns to UnL Press the SET button at least 4 seconds Release it when the display turns to LoC C...

Страница 20: ...ally operated machinery and equipment Compressed air can be dangerous if handled incorrectly Assembly handling or repair of pneumatic systems should be performed by trained and experienced operators 3...

Страница 21: ...ill cause it to break If you believe the lead wire is damaged and likely to cause malfunctions replace it 3 Confirm proper insulation of wiring Make sure that there is no faulty wiring insulation cont...

Страница 22: ...measures to prevent moisture from freezing in circuits when below 5 C since this may cause damage to the O ring and lead to a malfunction The installation of an air dryer is recommended for eliminatin...

Страница 23: ...torque for bracket mounting screw should be 0 98N m or less 1 Do not use in an environment with spattering liquid of oil or solvent 2 In an environment where the body of the switch is exposed to water...

Страница 24: ...RALIA SMC Pneumatics Australia Pty Ltd NEW ZEALAND SMC Pneumatics N Z Ltd EUROPE AUSTRIA SMC Pneumatik GmbH CZECH SMC Industrial Automation CZ s r o DENMARK SMC Pneumatik A S FINLAND SMC Pneumatics Fi...

Отзывы: