Description (Common to ZSE50F/ISE50 and ZSE60F/ISE60)
Displays
OUT 2 switch output status
Light up when ON
Use this button to change the mode
or set value.
Down button
LED (Red)
Use this button to change the mode
or set value.
Set button
Displays current pressure
Displays current mode
Displays error mode
3
1
/
2
digit LED
Displays
OUT 1 switch output status
Lights up when ON
LED (Green)
Use this button to change the mode
or set value.
UP button
Setting (Common to ZSE50F/ISE50 and ZSE60F/ISE60)
Calibration procedure
Initial setting
Manual
calibration
Auto preset
Detects and displays pres-
sure and operates switch.
Normal
operation
Value clear
Manual
fine adjustment
Peak hold
Key lock
Bottom hold
Unit conversion
P.14
P.16
P.14
P.15
Set "Output mode", "Res-
ponse time" and "Auto/
Manual mode."
The pressure set point is
calibrated automatically
at the time of adsorption
or primary pressure con-
firmation.
Enter the set value on
the pressure to perform
switch output.
Adjust the zero point of
atmospheric pressure.
Display unit can be
changed (for over-
seas use only).
The data set by
auto preset func-
tion is fine turned.
Prevents incorrect
operation such as
overwriting set po-
int value by mis-
take.
Can retain the ma-
ximum pressur dis-
played during me-
asurement.
Can retain the min-
imum pressure dis-
played during mea-
surement.
13
Approved
Series
ZSE F/ISE
50
60
50
60