![SMC Networks IDFB22E-11 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/smc-networks/idfb22e-11/idfb22e-11_operation-manual_1299745023.webp)
3 Operation / Shutdown
3
-
2
3-3
Shutdown
①
Turn off the ON/OFF switch.
②
The lamp will go out and then, the operation will stop. Depending on the condition of operation, hot air
continues to be emitted from the ventilation grille by the cooling fan for a while after turning off the switch.
3-4
Cautions about restart
・
Wait at least 3 minutes before restarting the air dryer after it has been shut down. Failure to do this may
cause safety devices to trip due to over load. If it is not possible to restart, refer to “Chapter 5
Troubleshooting.”
3-5
Check points before restart
Check following points before you start operation. If any abnormalities occur, immediately stop the operation.
Turn off the ON/OFF switch follow by the breaker of the main power supply.
•
There are no air leaks.
•
Air pressure, temperature, flow rate, and ambient temperature meet the specifications.
•
Moisture is being discharged from the drain tube.
•
The pointer of evaporating temperature indicates in the green zone.
•
There are no abnormal sound, vibration, or odor.