2 Transportation / Installation
2
-
4
Warning
・
To handle drain discharge, follow the safety guidelines such as wearing protective
goggles, apron, and gloves.
・
In cases where oil is mixed in the wastewater discharged from the auto drain, the liquid
would be considered as toxic waste and treatment is necessary in accordance with local
regulations.
2-2-5
Electric
Wiring
Warning
•
Only properly trained and qualified personnel are allowed to perform wiring
work.
•
Before wiring, you must disconnect the power. Do not work under any
energized conditions.
•
Supply power from a stable source that is free from the effect of surge.
•
Referring to “6-1 Specifications,” make sure to install a GFCI breaker that has
the right short circuit capacity and load capacity.
•
Supply power of the equipment should meet the specifications on page 6-1.
•
The equipment must be grounded for safety.
•
Do not connect ground wire to a water pipe, a gas pipe, or a lightening rod.
•
Do not plug too many leads into a single socket.
•
The customer must prepare for countermeasures of the power failure.
The dryer may not start normally at the moment of power failure.
•
Circuit breaker must be properly selected to meet safety standard of local
regulations.
•
Always be sure to connect the protective conductor first, disconnect it last in
respect to the other connections.
•
Be sure that the protective conductor has some additional length in respect to
the live conductors, so that it is not subject to mechanical stresses.
•
Be sure to install the circuit breaker correctly so that it disconnects all live
conductors and so that the operating handle can be easily accessible.
Specification of power cable
Prepare following power cable.
Power cable: 16AWG (1.25mm
2
), Three-cores (including the ground cable) [IDFB22E/37E], Four-cores
(including the ground cable) [IDFB55E/75E], External diameter: about 0.3inch (8mm) to 0.5inch (12mm).
Additional length of about 4inch (0.1m) is needed to wire inside of the equipment.