![SMC Networks IDFA22E-23-A Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/smc-networks/idfa22e-23-a/idfa22e-23-a_operation-manuals_1299744041.webp)
Air Dryer
12 Specification for Option T
12-1 Safety instructions
12 - 1
IDFA Series
IDX-OM-I076
12 Specification for Option T
This option installs a terminal block that has outputs for the operation and failure signals. The signals are
non voltage contact style. For details, refer to 12-2, 12-3 and 12-4.
12-1 Safety instructions
When handling the product, take care to the following precautions.
12-2 Specifications
This option installs a terminal block that has outputs for the operation and failure signals.
・
The operation and failure signals are non voltage contact style.
Operation
・・・・・
When the product is operating; Close
Failure
・・・
When the product stops due to failure; Close
・
Contact capacity
AC200V / 2A
DC24V / 2A
(Minimum applicable load: 20V / 3mA)
12-3 Remote operation
・
For the remote operation, turn on and off the power supply side under the condition of the Switch with
lamp ON.
・
Ensure at least 3 minutes is left after the unit is stopped before restarting it, even for the remote operation.
If the product is restarted within less than 3 minutes, protective equipment (overload relay) may activate
and prevent the product from restarting.
Additionally, the frequency to start and stop the operation must be restricted to 5 times per hour (to
prevent breakage of the motor).
Only qualified person must perform wiring and observing the following points.
1. Be sure to shut off the power supply before wiring. For safety, do not perform any work on the unit with
the power supply on. The power supply cannot be completely shut off just by turning off the Switch with
lamp. Be sure to turn off all power lines connected to the product.
2. Supply the power from a stable source, free from surges.
3. Be sure to mount the Ground Fault Circuit Interrupter (GFCI) with adequate sensitivity and load
capacity to prevent electrical shock and protect the refrigerating compressor motor from burning out.
4. Provide the power suitable for the product specifications.
5. Be sure to ground the product for safety. Without grounding, the GFCI can not operate normally.
6. Do not ground to water pipe, gas tube or lightening rod line.
7. Do not connect too many wires to the same outlet, which could results in heat generation and fire.
8. Do not retrofit the wiring of the dryer and the power supply line.
9. For the use of the product in Europe, mount the breaker compatible to IEC standard to the power supply
for the product.
Warning