![SMC Networks IDFA22E-23-A Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/smc-networks/idfa22e-23-a/idfa22e-23-a_operation-manuals_1299744023.webp)
Air Dryer
4 Maintenanc
e
4-2
Periodical Maintenance
4 - 2
IDFA Series
IDX-OM-I076
- Maintenance of the air dryer should only be carried out by someone with sufficient knowledge and
experience of air dryers and related equipment.
- Before carrying out maintenance, the important warnings in this manual must be thoroughly read and
understood.
- When replacing or cleaning parts of the air dryer, be sure to remove the compressed air pressure inside the
air dryer to “0”. Never remove the case assembly when the air dryer is operated or air pressure remains
inside. It is extremely dangerous if compressed air pressure remains inside the air dryer, as parts may come
flying off at speed when loosened, or other unexpected accidents.
- This product has parts that become hot during operation and a power supply with high voltage applied.
There is a risk of burns due to heat or electrification by high voltage. Even when operation is shut down after
switching off the air dryer’s illuminated light, there are also charging lines. When working on the charged
sections, be sure to switch off the earth leakage breaker installed before starting work.
- As some parts of the air dryer will remain hot, there is a risk of burns due to residual heat after the power is
switched off. So do not carry out replacement work until the temperature of these parts has fallen to 50
o
C or
less. Wait for about 10 to 15 minutes as a guide.
- When carrying out maintenance work on the auto drain strainer and auto drain, there is a risk of touching the
drain fluid during work. Please follow the safety procedure for operators specified by customer. (Example:
carry out work wearing safety glasses, apron and gloves to prevent discharged fluid from touching the
human body.)
- Use neutral detergent solution to clean parts such as the auto drain strainer and auto drain. Never use
solvent such as thinner.
- When removing the outer casing panel or case assembly of the auto drain, wear gloves to prevent injuries.
How to clean and replace the case assembly.
When carrying out maintenance work on the auto drain and auto drain strainer, please
follow the steps below.
- Turn off the Switch with lamp.
- Disconnect the earth leakage breaker at the power supply or unplug the power plug from the socket.
- Fully close the IN/OUT valves. Only open the bypass when compressed air is required during work.
- Only the point that is necessary for work please remove a decoration panel.
Warning
Danger