3-7.Auto switch
The type and specifications of applicable auto switch and the cautions for handling of them can be found on
the catalog and operation manual respectively.
3-7-1.Mounting position for detection at stroke end and Operating Range
Table 2 Unit:mm
Applicable bore size
A
B
Operating Range
Φ32
7.5
16.5
Φ40
12
23
Φ50
9
19
Φ63
19
24
7.5
Fig 3
3-7-2.How to mount auto switch
①Insert the rail into the mounting groove. Loosen the mounting screw in advance.
②Decide the position and tighten the screw.
Tightening torque:0.8~1.4N・m
Fig 4
-
11
-
Switch rail
Mounting screw
Auto switch