HRX-OM-O021
Chapter 5 Display and setting of various functions
5.18
Communication function
HRS Series
5-60
22.
Select parity check (simple communication protocol)
from the table below with [
▲
] key
or [
▼
] key, and confirm by pressing “SEL”.
Table 5.18-12
List of set value
Set value
Explanation
Initial value
(Default setting)
Setting/checking are not available unless the
serial protocol setting is simple
communication protocol.
None
○
Odd number
Even number
Stop bit
(
simple communication protocol
)
Setting and checking
23.
Press the [SEL] key once.
The set screen of stop bit (simple communication protocol) is displayed on the digital
display.
PV
SV
24.
Select stop bit (simple communication protocol) from the table below with [
▲
] key or [
▼
]
key, and confirm by pressing “SEL”.
Table 5.18-13
List of set value
Set value
Explanation
Initial value
(Default setting)
Setting/checking are not available unless the
serial protocol setting is simple
communication protocol.
1 bit
2 bit
○
Response delay time (simple communication protocol) Setting
and checking
25.
Press the [SEL] key once.
The set screen of response delay time (simple communication protocol) is displayed on
the digital display.
PV
SV