Chapter 2 Contact input/output communication /Analog output communication
HRL Series
2.3 Contact input signal
2-5
2.3 Contact input signal
There are 3 contact input signals.
Two of them can be customized by
the customer.
2.3.1
Setting of contact input signal type and form
The type of contact input signal can be set from the
to "4. Contact input signal form" screen).
Following items can be set for contact input signal 1 and 2:
・
Contact type
––selects [ N.O. ] (A contact) or [N.C] (B contact)
・
Signal form
–––selects [ALT] (alternate) or [MT] (momentary)
・
Signal type
–––selects “OFF” (disabled), “external switch” (external switch
signal) or “run/stop” (run/stop) signal., Run (run) signal, Stop
(stop)signal
Setting of
contact
input signal form
(1)
(2)
(3)