-35-
EX
※※
-OMR1012
•SI unit parameters (2)
Parameter
setting
No.
Parameter
Definition
Item
Content
Default
setting
By
E.O.
By
W.S.
Enable
Generates an error.
Val: 1 to 65000
4
8
Valve
ON/OFF
counter
Memorizes the
number of times
the valve is ON.
Generates error
per channel when
the operation count
exceeds the set
value.
3
Disable
Does not generate an
error.
○
○
○
9
Valve
ON/OFF
counter clear
Clears the valve
ON/OFF counter to
0. (Refer to page
method).
-
-
-
x
○
Auto
○
10 HDX
10 FDX
100 HDX
10
BUS IN port
setting
Sets the
communication
speed and
communication
method of BUS IN
for the unit.
100 FDX
Selects the required
communication speed
and communication
method
○
○
Auto
○
10 HDX
10 FDX
100 HDX
11
BUS OUT port
setting
Sets the
communication
speed and
communication
method of BUS
OUT for the unit.
100 FDX
Selects the required
communication speed
and communication
method.
○
○
1: This function is valid only when “Hold/Clear priority” of the system parameter is set to “Via software“.
2: Some PLC does not support an idle mode.
3: The count is memorized every 30 seconds per channel. When the power supply is turned on again, counting starts from the last value
memorized.
4: Times for setting is set value x1000 times.