-18-
No.EX
※※
-OME0014-F
Set-up steps
In PROFIBUS DP, a device database file called the Generic Station Description (GSD) file provides
configuration information specific to the device (ID number, data format, baud rate...).
The GSD file of the product depends on the address setting mode (selected by the address setting mode
switch).
GSD file: SMCA1409.gsd (In hardware setting mode)
SMCA1408.gsd (In software setting mode)
The procedure to set the master to enable the product is shown using SIEMENS STEP7 as an example.
(1) Copy the GSD file of the product (SMCA140*.gsd) to a directory of your choice.
(2) Start up STEP7, and execute “Options” – “Install GSD Files” from the HW Config tools.
(3) Open “View” – “Catalog”, and check that the “Valves” icon has been added to “PROFIBUS DP” –
“Additional Field Devices”. Drag and drop “EX250-SPR1(HW)” (file for hardware setting mode) or
“EX250-SPR1(SW)” (file for software setting mode)to add it to the PROFIBUS DP line.
(4) Download the above setting to PLC.
Click “Save
&
Compile” .After completion,
Click “Download to Module”.
It is set completion in the above.
It is set completion in the above.