Setting Procedures

Confirm the product is installed and connected properly and perform setting in the following
procedure.

  

   

   

  

 

     

   

  

   

   

    

     

!     

Setting

Example of Internal Circuit and Wiring (continue)

Output signal

means ON,      means OFF

Input signal

Signal through I/O cable

Actuator condition

OUT1

When motor side positioning completed

When end side positioning completed

When Intermediate stop positioning completed

During actuating

OUT2

OUT3

Command

IN1

Command to operate motor side

Command to operate end side 

Command to operate intermediate stop

IN2

Symbol

Connection of the motor and the controller 
(When controller separated type is used)

•Mind the direction of the connector and insert them until they click when connecting the cable.
•When pulling out the cable, pull them out while pressing connector lever.

Motor cable of

the actuator

Encoder cable of 

the actuator

Encoder cable of

the controller

Connector

Motor cable of

the controller

Lever

Lever

Connector

Turn off the power during connecting.

The slider may run suddenly.

Do not pull the cable forcefully when
removing attaching / detaching the 
connector.

Cable might be disconnected.

External operation allowed

Alarm occurring

OUT4

Symbol

Содержание e-Rodless E-MY2 Series

Страница 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Страница 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Страница 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Страница 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Страница 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Страница 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Страница 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Страница 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Страница 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Страница 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Страница 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Страница 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Страница 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Страница 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Страница 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Страница 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Страница 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Страница 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Страница 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Страница 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Страница 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...