Operation Characteristics

Specifications

Longer than 1s

Install power supply

READY output

Install power supply

Alarm output

READY output

2s or less

2s or less

When power supply is applied, the controller is initialized
and then READY output is performed.
If first transit of used power supply is 1s or more, the
alarm output is performed in prior to initialization and
READY output.
If emergency stop input is released, READY output is not
sent and alarm output is generated instead.

READY output

The input transmit drive command 2

The output for completion of positioning 1

State of operation

A

The output for completion of positioning 2

Operation

Stop

The input transmit drive command 1

Do not turn off input of drive command until
READY output is confirmed.
The signal for completion of positioning is out-
put when the actuator reaches the position
0.5mm before target position (indicated as A).

Application of power supply

Movement to end

Ex.)Movement from motor side to end side

Ex.)Movement from motor side to intermediate position

5ms or less

A

READY output

The input transmit drive command 2

The output for completion of positioning 1

State of operation

The output for completion of positioning 2

Operation

Stop

The input transmit drive command 1

Only if drive command 1 and 2 are input
within 5 msec, the intermediate operation is
performed. Input over 5 msec moves the
actuator to motor end or the other end.
The signal for completion of positioning is out-
put when the actuator reaches the position
0.5mm before target position (indicated as A).

Intermediate operation

Item

Specification

Operating 
temperature range

5 to 50 ºC

Acutuator

Controller (separated type)

Operating humidity range

Storage temperature range

5 to 40 ºC

35 to 85%RH (with no condensation)

-10 to 60 ºC (with no condensation and freezing)

Storage humidity range

35 to 85%RH (no condensation)

Withstand voltage

Between all of external terminals and the case: 500 VAC for 1 minute

Insulation resistance

Noise resistance

Between external terminal and case: 50 M

(500 VDC)

1000 Vp-p Pulse width 1 µs, Rise time 1 ns

Acquired certified standard

CE marking

Model

E-MY2C, E-MY2H, E-MY2HT

Item

Specification

Transfer speed acceleration

set range

Maximum load weight 

NOTE2)

Both ends

Intermediate

stopping position

10kg

2.5kg

100 to 1000 mm/s

Heavy load

Acceleration and deceleration method

Trapezoidal drive

Moving direction

Horizontal direction

Positioning points

Both ends (mechanical stoppers), 1 intermediate position

Intermediate stopping point positioning method

Direct teaching, JOG teaching

Positioning setting spot

Controller body

Display

LED for power supply, LED for alarming, LED for positioning completion

Input signal

Actuation command signal, Emergency stop input signal

Output signal

NOTE1) High speed is available only with E-MY2H and E-MY2HT.

NOTE2) The maximum load weight shows the motor abilitiy. 

Please consider it together with the guide load factor when selecting a model. 

NOTE3) Keep the resistance of the attached equipment not more than the allowable resistance. 

Positioning completion signal, Emergency detection signal, Ready signal

Repeated Positioning stop-
ping precision

0.01mm

0.1mm

Electric Specification

Power supply voltage

6mA or less / 1 circuit at DC24V(Photo-coupler input)

DC30V or less, 20mA or less / 1 circuit(opendrain output)

Input signal capacity

Output load capacity

Item

Specification

DC24V 10%

Max.5A(within 2s) normally 2.5A at DC24V

Power supply
for drive

Power supply
for signal

Emergency stop, Abnormal external output,Abnormal power supply, 

Abnormal drive,Abnormal temperature, Abnormal stroke,

Abnormality of motor, Abnormality of controller

Abnormal detection items

Current consumption

Current consumption

DC24V 10%

30mA output load capacity at DC24V

Power supply voltage

Standard specifications

Environment specifications

Standard speed

10 to 1000 mm/s

Low speed

50 to 1000 mm/s

Medium speed

0.25 to 2.45 m/s

2

Standard load

Medium load

Light load

0.49 to 4.90 m/s

2

0.98 to 9.80 m/s

2

1.96 to 19.6 m/s

2

Nominal size:25

Nominal size:16

5kg

1.25kg

20kg

5kg

10kg

2.5kg

200 to 2000 mm/s

High speed 

NOTE1)

Transfer speed set range

Allowable external resistance

Nominal size:25

Nominal size:16

10N

20N

Speed

Load type

Содержание e-Rodless E-MY2 Series

Страница 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Страница 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Страница 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Страница 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Страница 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Страница 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Страница 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Страница 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Страница 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Страница 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Страница 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Страница 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Страница 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Страница 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Страница 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Страница 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Страница 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Страница 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Страница 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Страница 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Страница 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...

Отзывы: