SAFETY

The e-Rodless Actuator and this manual contain essential information for the protection of users
and others from possible injury and property damage and to ensure correct handling.
Please check that you fully understand the definition of the following messages (signs) before
going on to read the text, and always follow the instructions.
Please read the operation manuals of related apparatus and understand it before operating the
actuator.

Read this manual and follow its instructions. Signal words such as WARNING, CAUTION and
NOTE, will be followed by important safety information that must be carefully reviewed.

IMPORTANT MESSAGES

Indicates a potentially hazardous situation which could result in death
or serious injury if you do not follow instructions.

Gives you helpful information.

Indicates a potentially hazardous situation which if not avoided, may
result in minor injury or moderate injury.

Do not use the product in the environment with possible presence of flammable,
explosive or corrosive gas with the product to prevent fire, explosion or corrosion.

Note the actuator doesn't have explosion proof construction.

During operation, do not enter your hand into moving range nor touch moving parts.

It may cause injury.

Do not disassemble, remodel (including change of printed circuit board) or repair.

An injury or failure can result.

Do not operate beyond specification range.

Fire, malfunction or switch damage can result.
Please use it after confirming the specification.

Do not perform operation and setting. 
Electric shock may occur.

The grounding should be performed separately at short length near controller if pos-
sible.

Be sure to ground the product to keep the capability of resistance for the noise in the actuator.

Ground with FG terminal.

Perform functional inspection after maintenance.

Stop operation when equipment or component doesn't work properly. Safety may not be guaran-
teed by unintended malfunction. 

Ensure the safety in wiring for ALM signal by inputting emergency stop signal and causing succes-
sive error.

Do not touch the side and lower part of motor and controller.

These parts become hot and should not be touched until it is confirmed they become cool enough.

Do not connect driving power supply and turn on it before the area where the work
(slider) is moved confirms safety.

The movement of the work may cause accident. And when power supply is turned on, the work is
returned to home position by input IN1 or IN2 signal. (Except that stroke learning is not performed
at all.) 

After the stroke is adjusted, turn on power supply and then perform stroke learning.

If the stroke leaning is not performed, the product may not operate along with the adjusted stroke
and damage the connected equipment.

Содержание e-Rodless E-MY2 Series

Страница 1: ...e Rodless Actuator E MY2 Series Operation Manual URL http www smcworld com...

Страница 2: ...INLAND 358 9 859 580 PORTUGAL 351 2 610 89 22 FRANCE 33 1 64 76 1000 SPAIN 34 945 18 4100 GERMANY 49 6103 4020 SWEDEN 46 8 603 0700 GREECE 30 1 342 6076 SWITZERLAND 41 52 396 3131 HUNGARY 36 1 371 134...

Страница 3: ...cause injury Do not disassemble remodel including change of printed circuit board or repair An injury or failure can result Do not operate beyond specification range Fire malfunction or switch damage...

Страница 4: ...re cycle Do not use where close to surge generating source Do not short the load Short of the load of the controller is indicated as error but it may cause over current and break the actuator Do not p...

Страница 5: ...er FG terminal Motor side End side Names and Functions of Individual Parts Controller integrated type Encoder cable of the controller I O cable Encoder connecting connector Motor connecting connector...

Страница 6: ...5 Tightening torgue 1 3 to 1 4N m L type bracket Controller Motor Mounting screw M4 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L an...

Страница 7: ...ch to move the actuator to intermediate position and set the intermediate position The switch to move the work to motor end The switch to move the work to the other end The rotary switch to set moving...

Страница 8: ...bnormal stroke Abnormality of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol C...

Страница 9: ...Command to operate motor side Command to operate end side Command to operate intermediate stop IN2 Symbol Connection of the motor and the controller When controller separated type is used Mind the dir...

Страница 10: ...ush of over 3s at least the product comes into learning mode and starts stroke learning 3 2 Confirm 2 indicator lamps MOTOR and END are lighting Since the actuator starts moving automatically to learn...

Страница 11: ...switch and the speed of actuator is set Rotary switch to set speed of movement to the direction of the motor side Rotary switch to set speed of movement to the direction of the end side 6 2 Setting of...

Страница 12: ...esistance Noise resistance Between external terminal and case 50 M 500 VDC 1000 Vp p Pulse width 1 s Rise time 1 ns Acquired certified standard CE marking Model E MY2C E MY2H E MY2HT Item Specificatio...

Страница 13: ...Red Power is turn on Symbol When positioning completed External input stop completed Motor side End side Intermediate 1 Intermediate 2 Intermediate 3 In case of alarm 2 State of indicator light light...

Страница 14: ...y of motor Abnormality of controller Abnormal detection items Current consumption Current consumption DC24V 10 30mA output load capacity at DC24V Power supply voltage Symbol Cable color Signal name Co...

Страница 15: ...intermediate stop 1 Command to operate intermediate stop 2 Command to operate intermediate stop 3 External input stop command IN2 IN3 Symbol Example of Internal Circuit and Wiring continue Connection...

Страница 16: ...at the center of the stroke Press again within 3s after pressing Press within 3s after pressing Press within 3s after pressing Travel to intermediate position 1 Travel to intermediate position 2 Trav...

Страница 17: ...moved the intermediate position is changed On the other hand change of the position of the stroke adjusting unit at stroke does not make sense If the stroke is set shorter than the distance between th...

Страница 18: ...not turn off input of drive command until READY output is confirmed The signal for completion of positioning is output when the actuator reaches the position 0 5mm before target position indicated as...

Страница 19: ...drain output Input signal capacity Output load capacity Item Specification DC24V 10 Max 5A within 2s normally 2 5A at DC24V Power supply for drive Power supply for signal Emergency stop Abnormal exter...

Страница 20: ...m alarm reset Abnormal drive Max output is continued for prolonged period Check the weight of work and foreign material attached to actuating part and then perform alarm reset Tuming off Ligting blink...

Страница 21: ...om alarm condition Alarm output Longer than 50ms Emergency stop input READY output contact is opened External alarm reset Even if alarm occurs it recovers from alarm condition by inputting emergency s...

Отзывы: