- 19 -
3-2. Checks
3-2-1 Daily check
1) Smoothness of the operation
2) Changes in piston speed and cycle time
3) Proper stroking
3-2-2 Regular check
1) Looseness of mounting nuts and rod end nuts
2) Looseness of mounting frame and excessive deflection
3) Smoothness of the operation
4) Changes in piston speed and cycle time
5) External leakage
6) Proper stroking
7) Damage to the piston rod
8) Whether drainage in the air filter is regularly discharged or not.
Check the points above at least, and retighten or contact the sales representative if any
failure is found.
Warning
1) Maintenance should be performed according to the items above.
Improper handling can cause damage and malfunction of equipment and machinery.
2) Removal of equipment, and supply/exhaust of compressed air
When equipment is serviced, first confirm that measures are in place to prevent dropping
of driven objects and run-away of equipment, etc. Then cut the supply pressure and
power, and exhaust all compressed air from the system using its residual pressure
release function.
When machinery is restarted, check that operation is normal with actuators in the proper
positions.
3-3. Consumable parts
3-3-1 Replacement parts
The replacement parts can be ordered as shown below.
Table 4
φ20
φ25
φ32
φ40
Rod seal
CM20Z-PS
CM25Z-PS
CM32Z-PS
CM40Z-PS
The rod seal is not delivered in sealed packaging for storage independently, so it must
be used within 1 year.
When storage for a longer period is expected, enclose it by packaging (by putting into
a polyethylene bag and containing in a box), and store in the following manner.
!