46
interface that pan-tilt camera cradle will
accept. When the length of RS-485 connection
is very long (longer than 200M), it’s not
recommended to use high speed connection
(greater than 2400bps).
-
Data Bits: Select data bits of RS-485
connection.
-
Parity: Select parity bit: odd, even, or space.
-
Stop Bit: Select stop bit: 1 or 2.
-
Home/Up/Down/Left/Right:
Input
the
command string used to move pan-tilt camera
cradle to home or up/down/left/right
position. You can click ‘ Test’ button to send
command string for testing.
-
Command 1 ~ 5: You can define extra pan-tilt
camera cradle control strings here by giving it
a name (Command Name) and command
string (Hexadecimal Message). You can also
click ‘ Test’ button to send command string for
testing.
When you finish with above settings, click ‘Apply’ button to save