Humidity <95%
Temperature range between -30°C and +50°C
Vibration: Frequency <55Hz Max. Movement <0.35mm
Do not use equipment in explosive atmospheres (contact the manufacturer for
further advice).
Noise generated by the equipment will never exceed 70 dB
Heaters
The T4 (053B) series includes a heater system as standard. The heaters are
activated when the temperature drops below 0°C and automatically switch off
when the temperature rises above it again.
Detection Zone width (DZ) (K)
The detection zone width or protected height must be of a suitable size for each
application to prevent personnel access to the danger area. This can be over,
under or around the light curtains detection zone.
Object Detection Capability (ODC) (N)
The minimum size of object guaranteed to be detected when placed in the light
curtain’s infrared sensing field. A test piece of appropriate size is provided to test
that the light curtain object detection capability is within the parameter specified
for the particular model number. Transparent objects are not detected.
Range (R)
This is the maximum scanning range of the light curtain between the Transmitter
(TX) head and Receiver (RX) head. Ensure the light curtain is capable of
satisfying the range requirement for the particular application it is being used for.
Reset Location
Reset devices must be located such that the danger area can be seen to be clear
of persons before the system is activated. The reset device should not be
accessible from inside the danger area.
Содержание 053B101
Страница 1: ...T4 053B SERIES SAFETY LIGHT CURTAINS INSTALLATION GUIDE MACHINERY SAFETY SYSTEMS...
Страница 7: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 3 Figure C Operating Requirements...
Страница 12: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 8 Figure E Electrical Connections...
Страница 19: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 15 Figure G Mechanical Information...
Страница 40: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 36 Figure O Declaration of Conformity...