There are four options,
1) OFF
2) 1 beam
3) 2 adjacent beams
4) 3 adjacent beams
These options are selectable at DIP switches 1 & 2 as shown in the diagram
below in the direct settings mode.
The floating blanking function is particularly useful for those applications where,
for example, a work piece is moving up and down within the infrared field of the
light curtain as part of the manufacturing process. This allows the operator to
manipulate the work piece safely without shutting down the machine.
Using the floating beam blanking function of the T4 (053B) series safety light
curtain will change the original Object Detection Capability (ODC). The table
below shows the change to the original ODC (14mm, 30mm and 40mm) when
using the 1, 2 or 3 beam floating blanking options.
Floating Beam Blanking (14 mm Detection Capability)
Beams Blanked
0
1
2
3
Object Detection
Capability (ODC)
14 mm
24 mm
33 mm
43 mm
Floating Beam Blanking (30 mm Detection Capability)
Beams Blanked
0
1
2
3
Object Detection
Capability (ODC)
30 mm
55 mm
80 mm
105 mm
Floating Beam Blanking (40 mm Detection Capability)
Beams Blanked
0
1
2
3
Object Detection
Capability (ODC)
40 mm
63 mm
88 mm
113 mm
1
2
3
4
5
6
ON OFF
OFF
1
2
1
2
1
2
1
2
1 Beam
2 Adjacent Beams
3 Adjacent Beams
Содержание 053B101
Страница 1: ...T4 053B SERIES SAFETY LIGHT CURTAINS INSTALLATION GUIDE MACHINERY SAFETY SYSTEMS...
Страница 7: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 3 Figure C Operating Requirements...
Страница 12: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 8 Figure E Electrical Connections...
Страница 19: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 15 Figure G Mechanical Information...
Страница 40: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 36 Figure O Declaration of Conformity...