T4 (053B) Series
Installation Guide
CD354/220116
Smartscan Ltd
22
2)
Mute Time Out Period
A maximum pre-determined time the light curtain will remain in a muted condition.
The standard or default setting is 15 minutes. After the 15 minute mute time out
period the light curtain’s safety outputs (OSSDs) will turn OFF and initiate a
machine stop condition. Use of the infinite mute time out must be subject to the
detailed risk assessment.
There are two options
1) 15 minutes
2) Infinite
These options are selectable at DIP switch 3 in the direct settings mode.
Warning
Floating Beam blanking increases the size of the object that
the safety light curtain can detect resulting in an increased Object
Detection Capability (ODC).
When selecting 1, 2 or 3 beam floating blanking the worst case ODC
should always be taken into account during the risk assessment process.
Check that the position of the light curtain in relation to the nearest
danger point (Separation distance) meets the requirements of European
Standard ISO 13855.
Note
: If the parity or any of the DIP switches are changed while the light
curtain is in operation the OSSDs (safety outputs) will turn OFF and
remain OFF. All DIP switch setting must be done with the power to the
light curtain disconnected. Refer to the Parity setting section.
OR
15 minutes
Infinite
∞
1
2
3
4
5
6
ON OFF
Содержание 053B101
Страница 1: ...T4 053B SERIES SAFETY LIGHT CURTAINS INSTALLATION GUIDE MACHINERY SAFETY SYSTEMS...
Страница 7: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 3 Figure C Operating Requirements...
Страница 12: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 8 Figure E Electrical Connections...
Страница 19: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 15 Figure G Mechanical Information...
Страница 40: ...T4 053B Series Installation Guide CD354 220116 Smartscan Ltd 36 Figure O Declaration of Conformity...