11
Troubleshooting & Precautions
Troubleshooting
1. The unit does not correspond when it is switched on.
Check the fuse at lower right side of the unit and replace it (5A) if it is damaged or broken.
2. There is leakage in the fuel distributor coupler.
Check the O-rings and replace it if it is damaged or unfitted. Do not tighten the two riffle screws too tightly;
otherwise, it may cause leakage.
3. When running, there is no working pressure.
New machine is first used, or the machine has not been used for a long time, there may be no fuel pressure.
At this time, select the
First Using
function in the
System Function
, and then operate according to the
following:
a. According to the instructions, connect the test connector on the fuel outlet pipe and insert it into the
Fill
Port
.
b. Then, run the function.
c. When there have liquid out from the test adaptor, stop it. If not stop, it’ll stop automatically after 30s.
d. Now it can use normally.
Note: if there have no liquid out, you can run it again.
Connect the test adaptor to the outlet pipe
Insert it into the
Fill Port
Select the
Setting Function
Select the
First Use
function
4. The buzzer rings continually when there is no fuel pressure.
The machine has fuel-lack warning function and it will ring when the liquid in the fuel tank is lack, and then
automatically switch off the fuel pump and injectors and returns to the stop state. Supply the detergent or
test liquid to stop ringing.
5. Draining the test liquid in glass tube thoroughly requires pressing the
DRAIN
icon more times.
The solenoid valves will stop automatically after 15 seconds and it is necessary to drain more times if there
is more liquid.
Precautions
1) Do not place anything on the control panel to prevent from breaking the measuring cup because it is made
from vulnerable.
2) Do not disconnect hose before the system pressure reaches “0”.
3) Always ensure that the provided power supply is well contacted with ground safely.
4) The unit is designed with warning function. When the level switch checks the liquid inside the tank less
than the lowest line, the unit will utter the warning sound and meanwhile stop the fuel pump and injectors
automatically, and then the unit returns to the stop state. The unit will stop warning until the liquid is
supplied enough, at this time pressing the
ENTER
key will run the unit again.
5) Clean the control panel in time and Keep the pulse signal cable away from the liquid.
iSmartINC 605 Injector Cleaner & Tester