![SmartSafe iSmartINC 605 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/smartsafe/ismartinc-605/ismartinc-605_instruction-manual_1298217014.webp)
10
1-Injector Cleaner & Tester; 2-Engine; 3-stopper; 4- Fuel-inlet hose to engine;
Tidy up after cleaning
a) After the cleaning is completed, turn off the Ignition Switches restitute the link of the fuel hoses then start
and check the leakage of fuel system.
b) At last please clean the fuel tank and hose line with test liquid (if there is residual detergent inside fuel tank,
please.)
c) Tidy up and make preparation for the next cleaning.
Note:
1) When cleaning, care must be taken as the detergent is inflammable. Prepare for a fire extinguisher.
2) Be sure that all hose lines are well connected and there is no leakage on the hose lines before
performing cleaning.
Transporting and Storing
Transporting
A. Before being packed, the liquid inside the fuel tank should be drained completely to avoid overflowing as
transporting.
B. Move only by hand or lift with soft belt.
C. No package no lifting tools or long-distance transportation.
D. To prevent the unit from shocking and knocking, make sure it is on the base seat and in the packing case
during transportation. Firstly pack the unit with the matter similar with plastic strip and add the filling
material (such as foam or sponge, etc.) between the unit and packing case to avoid scratching the surface
when the unit shakes.
E. Make sure that the maximum incline angel does not exceed 45. Do not place the unit up-side-down.
Storing
A. Store only in dry area and keep away from water before the unit is unpacked.
B. Store the machine in well-ventilated area and do not expose it to direct sun shine or rain.
Installation Environment
A. Keep a distance of no less than 200mm between the unit and any wall or other substance. The unit should
be put in well-ventilated area. Make sure the temperature is within -10
℃
+40
℃
.
B. The unit has been well grounded for safety operation. Please confirm that the power socket is also well
grounded.