closed state. Uniformity test can be done at this state. When DRAIN icon is pressed, solenoid

valve will drain oil.

b)

The system pressure can be adjusted by pressing

or

key at testing.

c)

During operating, the user can select parameter, such as RPM or PW, and then press

or

key

to achieve the status of the simulation.

d)

Good injectors may have identical injecting angle, uniform spraying but no jet. Otherwise, replace

the injector.

e)

In the sprayability test, a special electrical parameter--the minimum injection pulse width of

injector--can be tested, to compare the injectors on the same engine. That is to set cylinder No.,

start the test from minimum injection pulse width, and then gradually increases the pulse width till

the injector starts injection (observed with the help of backlight). The value set at this moment is

the minimum injection pulse width, so the difference of minimum injection pulse width among

these injectors could be observed.

Leakage Test

Leakage test is to inspect the sealing conditions of the injector needle valve under system pressure and to find

out if the injector is dribbling.

Procedures (Installation refer to Uniformity/ Sprayability Test):

1) Before doing leakage test, please press

DRAIN

icon to drain the rudimental residual test liquid from the

measuring cup.

2) Select

Leakage Test

function and press

ENTER

key to run.

At this time the system pressure can be adjusted by pressing

or

key to observe dribbling from the

injector the pressure is adjusted preferably 10% higher than manufacturer’s specifications.

3) When the test is over, the equipment will automatically stop and the buzzer will ring simultaneously.

Note:

In general the drip of the injector should be less than 1 drop within 1 minute (or in accordance with the

specifications). The default time of the system is 1 minute.

Injecting Volume Test

Injecting volume test is to check if the injecting flow in 15 seconds meets the specifications for injecting amount.

The deviation reflects the wear or clogging in the injector, instead of electrical parameter variation.

Procedures (Installation refer to Uniformity / Sprayability Test):

1) Before this test, press

DRAIN

icon to drain the test liquid from the measuring cup if there is any.

2) Choose

Injecting Volume Test

function and press

ENTER

key to start the test.

Adjust the fuel pressure by pressing

or

key according to the injector specification.

3) When the test is over, the equipment will stop automatically at the ring of the buzzer.

iSmartINC 605 Injector Cleaner & Tester

Содержание iSmartINC 605

Страница 1: ...iSmartINC 605 Injector Cleaner Tester i iSmartINC 605 Injector Cleaner Tester...

Страница 2: ...s rated for lower current than that of the equipment may overheat e Always unplug equipment from electrical outlet when the machine is not in use Never pull the cord when unplugging from the outlet f...

Страница 3: ...list Introduction 2 Functions 2 Features Specifications Structure Overview Control Panel Installation Connection First Use Or reuse after long time storage Operating Procedures Preparation Cleaning t...

Страница 4: ......

Страница 5: ...eaning to remove the carbon deposition on vehicle Setting To set the system language Inquire To check the equipment usage information Information To check the hardware and software version Features Ad...

Страница 6: ...t left cover 9 Drain port for ultrasonic cleaner 10 Cabinet front cover 11 Cabinet operate cover 12 Compression screw 13 Fuel distributor 14 Top supply connector 15 Glass tube 16 Pressure gauge 17 Doo...

Страница 7: ...ht cover 33 Screw 34 Cool fan 35 Fuel tank 36 Backplane 37 Cabinet back cover 38 Pulse signal line base 39 Screw 40 Solenoid valve bracket 41 Air solenoid valve 42 Draining solenoid valve 43 Bracket 4...

Страница 8: ...the test adaptor to the outlet pipe and insert it into the Fill Port 3 Power on select the System Function and then select the First Use function 4 Run it 5 When there have liquid out from the test a...

Страница 9: ...Statement the equipment can be operated normally without connecting compressed air This function is only to enhance the test and cleaning effect Note this function is OFF by default We specially desig...

Страница 10: ...ter control panel with soft cloth 4 Drain the test liquid from the tank into a container to avoid volatilization Store the test liquid in a safe place if it can be used again or dispose of it in accor...

Страница 11: ...Otherwise damage may be incurred Do not let the pulse signal cables or plug dip in the injector s body into the detergent Uniformity Sprayability Test Uniformity test is to find out the difference of...

Страница 12: ...yability Test 1 Before doing leakage test please press DRAIN icon to drain the rudimental residual test liquid from the measuring cup 2 Select Leakage Test function and press ENTER key to run At this...

Страница 13: ...utlet hoses throttle and combustion chamber So the fuel supply system combustion chamber and injector of the engine must be cleaned on a timely basis Combustion Chamber cleaning is a solution that can...

Страница 14: ...transportation D To prevent the unit from shocking and knocking make sure it is on the base seat and in the packing case during transportation Firstly pack the unit with the matter similar with plasti...

Страница 15: ...rings continually when there is no fuel pressure The machine has fuel lack warning function and it will ring when the liquid in the fuel tank is lack and then automatically switch off the fuel pump a...

Страница 16: ...ble to general repair Under the state of turning on the power the electrical system inside the unit contains the factor causing danger Failure to comply with these instructions could result in death o...

Отзывы: