CAT-601S Auto Transmission Cleaner and Fluid Exchanger User’s Manua
l
16
Fig.56
Print information can choose print output content. The
information contained in the options that are not selected
cannotbe printed out, as shown in Fig.57.
Fig.57
9.9 History Records
The History Records can be used to check the change
amount and time of new fluid, used fluid and detergent.
After the filters are exchanged with the new ones, it is
required to delete the original history records, otherwise
the filter status icon on the interface will not be displayed
correctly. Do not delete the original history records until
the fluid filters are exchanged, otherwise it will influence
your correct judgement to the status of the filters. When
the added fluid change amount is more than 3600L, the
system will prompt that the fluid filters are abnormal(i.e.
the filter status icon on the interface will turn orange from
green), as shown in Fig.58. It is suggested that the fluid
filters should be replaced in this case.
Fig.58
After replacing the fluid filters, press key DEL two times
on the interface of History Records to delete the original
history records, and mean while delete the prompts for
abnormal fluid filters(i.e. the filter status icon on the
interface will automatically turn green from orange), as
shown in Fig.59.
Fig.59
9.10 Device information
Select the device information option and press OK key.
The device information is displayed as shown in Fig.60.
Fig.60
Warning
Warning sound: When there is no fluid in the new tank or
the operation is completed, the unit OKs the standby
state.
Maintenance
Pay attention to each connection to check if there is
any leakage during fluid exchange. When any leak is
found, stop the CAT-601S immediately and check for
the unit. Start to exchange fluid again after
reconnection is made.
Before cleaning up the unit, the used fluid should be
drained out from the used fluid tank and the new
fluid should be drained out from new tank and stored
in container after every usage to protect the
electronic scale is on the no load state at non-work
condition.
Keep the new fluid tank clean.
Please recalibrate the electronic scale after replacing
the main-board and/or the electronic scale itself.