2-2
2.3 Specifications
Welding Output
Welding Current Range
5 - 100 Amps
Nominal DC Open Circuit Voltage (OCV)
60V
Welding Output, 104º F (40º C), 10 min.
(quoted figures refer to SMAW output)
50A / 22V @ 100%
80A / 23.2V @ 30%
90A / 23.6V @ 20%
Rated Input Current (A) for STICK Welding
33.5A
[email protected]
I
ο
= 90A @ 23.6V
Rated Input Current (A) for TIG Welding
21.0A
Io = 100A@14V
Rated Output for STICK Welding
90A / 23.6V @ 20%
Rated Output for TIG Welding
100A / 14V @ 20%
Duty Cycle (%)
20% @ 90A / 23.6V
Welder Type
Inverter Power Source
Output Terminal Type
Dinse® 25
Mains Power
Number of Phases
Single Phase
Nominal Supply Voltage
115V
Nominal Supply Frequency
50/60 Hz
Effective Input Current (l1eff)
15.0 Amps
Maximum Input Current (l1 max)
Δ 33.5 Amps
Classification
Protection Class
IP23S
Standards
IEC 60974-1
Cooling Method
Fan Cooled
Dimensions and Weight
Welding Power Source Mass
9.7 lb. (4.4 kg)
Welding Power Source Dimensions
(Height x Width x Depth)
H 13.0" x W 5.1" x D 9.0"
(H 330mm x W 130mm x D 230mm)
The recommended time delay fuse or circuit breaker size is 30 amp. An individual branch circuit capable of
carrying 30 amperes and protected by fuses or circuit breaker is recommended for this application. Fuse
size is based on not more than 200 percent of the rated input amperage of the welding power source
(Based on Article 630, National Electrical Code).
Smarter Tools continuously strives to produce the best product possible and therefore reserves the right to
change, improve or revise the specifications or design of this or any product without prior notice. Such
updates or changes do not entitle the buyer of equipment previously sold or shipped to the corresponding
changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment
may differ from the above specifications due to in part, but not exclusively, to any one or more of the
following; variations or changes in manufactured components, installation location and conditions and local
power grid supply conditions.
Содержание ARC-100S
Страница 48: ...5 3 5 3 System Schematic ...
Страница 49: ...5 4 5 4 Parts List ...
Страница 53: ...5 3A 5 3 Esquema del sistema ...
Страница 54: ...5 4A 5 4 Lista de piezas ...
Страница 56: ......