Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 32 of 53
Normally, the status lights will be off. When a switch is pressed, the
corresponding light will be illuminated. When a status light is flashing, the
corresponding switch is calibrating, and the switch should not be pressed.
The system controller will ignore the switch while it is calibrating.
4.
If the system controller is powered on, but the generator is not running and no
buttons are pressed for 5 minutes, the system will enter Quiescent mode. In
Quiescent mode all displays are blank to conserve power. To return to Normal
mode from Quiescent mode, press the Mode switch.
5.
Whenever the PTO is engaged and the system controller is in Normal or Quiescent
mode, the generator can be switched from an “off” state to an “on” state, and vise-
versa, by pressing the “on/off” switch on the Command & Control Center. If the
PTO is not engaged or the hydraulic pressure is too low when the “on/off” switch is
pressed, the following screen will be displayed (reference Figure 18):
Example of low hydraulic pressure display
Figure 18
6.
If the system controller has been set to “auto-start”, the generator will begin to
produce power whenever the PTO is engaged. See installation instructions for the
directions to select the “auto-start” options.
7.
Additional Information provided by the Command & Control Center:
a. When the Command & Control Center is in Normal mode, pressing the Mode
switch once will display the oil temperature (reference Figure 19).