Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 14 of 53
WARNING:
Do not install hose ends until proper hose length has been determined.
Never install a hose in a location where it will rub against an abrasive surface or
sharp edge or corner.
Do not position hoses with tight bend radii. Consult the hose manufacturer’s
installation guidelines. Tight bends may kink and cause serious damage to the
system and will void the syste
m’s warranty.
Use caution when tightening the hose ends to prevent the hose from becoming
twisted.
Never install a 90° fitting at the pump inlet or outlet. Avoid the use of flow
restricting fittings.
Do not form loops in the hose that may collect air or kink. Run hoses as straight as
possible (but not taut) between connections.
Do not exceed hose lengths of 20 feet.
6.
Mounting considerations:
The SPS models HR-12 and HR-15 have been specifically designed to be mounted
on top of a vehicle, in the open, without requiring any additional coverings.
Reference Figure 3, Figure 4, and Figure 5 for minimum clearances around the
perimeter of the generator’s tray assemble. Also, do not position any obstructions
directly above the system’s oil cooler. If a system cannot be installed without
maintaining the minimum clearances as indicated, or if you have any questions
relative to the installation of a HR-12 or a HR-15, contact Smart Power
®
Systems at
(231) 832-5525.