A. C. MODULAR GENERATOR SYSTEM
Page 16 of 53
Figure 4
Left side view of HR-12/HR-15 tray assembly showing minimum clearance
for proper ventilation
Figure 5
WARNING:
Do not mount the hydraulic pump, tray assembly or reservoir in any location that is
not well ventilated. External heat sources elevating the hydraulic fluid and/or the
generator temperature will result in premature wear and degraded system
performance and void the system’s warranty.
7.
The tray assembly must be mounted in a position that is higher than the pump. If
the pump inlet hose is 10’ in length or less, the tray and reservoir assemblies must
be a minimum of 12” higher than the pump. If the pump inlet hose is longer than
10’, elevate the tray and reservoir assemblies an additional 12” for every additional
10’ of pump inlet hose length. See below for examples of minimum tray assembly
elevations above the pump:
Pump inlet hose length
Minimum tray and reservoir elevation
(above pump)
0
– 10 ft.
12 inches
15 ft.
18 inches
20 ft.
24 inches