-13-
Setting Auto-Close Mode
Auto-Close Mode allows the gate to close automatically
once the PE safety beam has been tripped and the
preset time has elapsed. This function is only available
with the addition of a functioning photo-electric safety
beam (Factory Default = Off).
Auto-Close Mode
allows you to set a timer from
001–180 seconds before the door begins to close. In
this mode the door will close if the photo beam is not
triggered after the time has elapsed.
Important:
If the photo beam is tripped within the time
limit the door will close 5 secs after the beam is restored.
PE Close Mode
allows the door to close 5 secs after the
photo beam has been tripped.
Important:
The door will remain open until the beam is
tripped.
Sequence Mode
allows the door to close 5 secs after
both photo beams (usually placed on either side of the
doorway) have been tripped.
Important:
The door will remain open until both beams
are tripped.
1.
Make sure that a functioning PE beam is connected
and Photo Beam Mode is set to On as per Page 11.
2.
Press
MENU
for 3 secs then press
SET
to cycle
through to
Auto-Close
or
PE Close
or
Sequence Mode
.
3.
Press
MENU
to choose
On
.
4.
Press
SET
to confirm and move to next item or press
MODE
to exit to normal operation.
Setting Auto-Close Timer
Delay
Auto-Close Time delay is used with Auto-Close Mode to
allow the gate to close automatically after the timer has
elapsed.
Note:
Auto-Close Mode must be enabled to use this
function.
1.
Press
MENU
for 3 secs then press
SET
to cycle
through to
Auto-Close
Delay
.
2.
Press and hold
MENU
to increase or PB to decrease
delay time in 1 sec increments (Max. 180 secs).
3.
Press
SET
to confirm and move to next item or press
MODE
to exit to normal operation.
Setting Pedestrian Auto-
Close and Timer Delay
If Pedestrian Mode is activated the above functions are
also available for Pedestrian Mode. Follow the above
procedure to enable auto-close and set a time delay as
required.
Auto Close
On
PE Close
On
Auto Close
060 Secs
Fig. 21
Fig. 22
Fig. 23
© June 2009 Smart Openers Pty Ltd