SMA
Technologie AG
Technical Data
Installation Guide
SBTLHCMS-IEN080411
Page39
Default
Used for setting the country-specific information.
GER/VDE0126-1-1: Country-specific parameter settings for Ger-
many in accordance with DIN VDE 0126-1-1
GB: Country-specific parameter settings for Great Britain
IT: Country-specific parameter settings for Italy
Other: Here, parameter settings can be defined for countries for
which no predefined setting exists.
Trimmed: If country-specific parameters have been changed,
"trimmed" is shown in the display.
dFac-Max
Maximum "mains frequency change" before the mains monitor-
ing system disconnects the device from the mains supply.
dZac-Max
Maximum "grid impedance change" before the grid monitoring
system disconnects the device from the grid.
E_Total
Total energy yield for the inverter. This change may be neces-
sary when you exchange the Sunny Boy and want to use the
data from the old device.
Fac-delta-
Maximum frequency, above (Fac-delta+) and below (Fac-delta-)
the mains frequency, before the mains monitoring system discon-
nects the device from the mains supply.
Fac-delta+
Fac-Tavg
Averaging time of grid frequency gaging
Firmware-BFR
Firmware version of the operation control unit (BFR)
Firmware-DC-BFR
Firmware version of the DC operation control unit (DC-BFR)
FirmwareSRR
Firmware version of the current control unit (SRR)
h_Total
Total hours of operation for the inverter. This change may be
necessary when you exchange the Sunny Boy and want to use
the data from the old device.
Hardware-DC-BFS
Hardware version of the DC operation control unit (DC-BFR)
Inst.-Code
Parameters for self contained power system recognition can only
be changed after entering the SMA grid guard password.
Name
Explanation
Содержание SB 4200TL HC
Страница 2: ......
Страница 6: ...Explanation of the Symbols Used SMA Technologie AG Page 6 SBTLHCMS IEN080411 Installation Guide...
Страница 10: ...Safety Instructions SMA Technologie AG Page 10 SBTLHCMS IEN080411 Installation Guide...
Страница 30: ...Installation SMA Technologie AG Page 30 SBTLHCMS IEN080411 Installation Guide...
Страница 44: ...Technical Data SMA Technologie AG Page 44 SBTLHCMS IEN080411 Installation Guide...
Страница 46: ...Inspection of the Electronic Solar Switch SMA Technologie AG Page 46 SBTLHCMS IEN080411 Installation Guide...
Страница 60: ...The Communications Interface SMA Technologie AG Page 60 SBTLHCMS IEN080411 Installation Guide...
Страница 63: ......