![SMA CLUSTER CONTROLLER Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/sma/cluster-controller/cluster-controller_user-manual_1294244050.webp)
8. In the field
Server path
, enter the subdirectory to which the Cluster Controller is to save the
data on the external FTP server.
9. In the field
Server
, enter the name or the IP address of the external FTP server.
10. Select [
Save
].
11. Perform a connection test. Select [
Execute
] in the field
Connection test
.
☑ The Cluster Controller performs the connection test.
OK
is displayed in the field
Result of the
last connection test
.
✖ The connection test has failed?
• Rectify the error (see Section 18.2, page 96).
Deactivating the FTP Push Function
1. Select the Cluster Controller in the system tree and select the menu
Settings
in the device
menu.
2. Select the parameter group
Further Applications > FTP Push
.
3. Select [
Edit
].
4. Deactivate the export of system data:
• In the field
Data export in CSV format
, select the entry
No
.
• In the field
Data export in XML format
, select the entry
No
.
5. Select [
Save
].
8.6.2
Testing the FTP Push Function
1. Select the Cluster Controller in the system tree and select the menu
Settings
in the device
menu.
2. Select the parameter group
Further Applications > FTP Push
.
3. In the field
Connection test
, select [
Execute
].
☑ The Cluster Controller performs the connection test.
OK
is displayed in the field
Result of the
last connection test
.
✖ The connection test has failed?
• Rectify the error (see Section 18.2, page 96).
8 Exporting System Data
SMA Solar Technology AG
User Manual
ClusterController-BA-en-15
50