In general different criteria can be defined for each port/VLAN/priority. Up to 64 Ingress Filtering Policy
resources can be defined and each bandwidth profile defined on the basis either of LAN port, VLAN or
VLAN+priority consumes 1 of such resources.
In order to define the bandwidth profile, the following parameters must be configured:
•
CIR (Committed Information rate): it is the admitted ingress rate (“green” coloured), with values
between 0 kbit/s and 1 Gbit/s
•
CBS (Committed Burst Rate): it is the maximum size of the token bucket of the green packets, with
values between 0 byte and 128 kbyte.
•
EIR (Excess Information Rate): it is maximum ingress rate admitted when possible (“yellow” col-
oured), with values between 0kbit/s and 1Gbit/s.
•
EBS (Excess Burst Rate): it is maximum size of the token bucket of the yellow packets, with values
between 0 byte and 128 kbyte.
•
CF (Coupling Flag): if enabled, the excess token (if any) charged into the green bucket are moved
into the yellow packet bucket.
Red packets, i.e. the ones exceeding the CIR+EIR rate, are automatically discarded. In other words, the
rate obtained with the sum of CIR+EIR is the maximum rate allowed to be transmitted.
The combination of CIR and EIR rates is typically referred to as PIR, or Peak Information Rate, which
represents the total burstable bandwidth sold to the customer.
According to MEF 10.2 (Metro Ethernet Forum) specifications, the “bandwidth profile” service attribute (In-
put Filter Policing), which includes some or all of the above categories, can be defined per UNI, per EVC or
per CoS identifier (CoS ID; EVC.CoS). For any given frame, however, only one such model can apply. The
service provider meets the bandwidth guarantees by reserving appropriate network resources and employ-
ing a two-rate/three-colour (trTCM) rate-limitation methodology as part of its traffic engineering policy to
ensure compliance by user traffic.
•
Green = Trasmitted:
CIR and CBS.
•
Yellow = Low Priority (dropped in case of congestion): EIR and EBS.
•
Red = Dropped:
traffic exceeding EIR and EBS is dropped.
For any port it is possible to add a Input Filter Policy table with this selections:
•
Disable
•
Uni Port Based
•
EVC C_Vid Based
•
COS C_Vid + Priority Based
•
EVC S_Vid/C_Vid Based
•
COS S_Vid/C_Vid + Priority Based
According the status of 802.1q Management> 802.1q settings =
•
Disable: you can select only Uni Port Based with CIR, EIR, CBS and EBS; Cf disable is ok.
•
Fallback: two selections 1) EVC C_Vid Based: applied to a CVLAN C_Vid with CIR, EIR, CBS and
EBS; Cf disable is ok. 2) COS C_Vid + Priority Based: applied to a CVLAN C_Vid with priority range,
CIR, EIR, CBS and EBS; Cf disable is ok.
•
Secure: two selections 1) EVC S_Vid/C_Vid Based: applied to a SVLAN S_Vid and a CVLAN C_Vid
with CIR, EIR, CBS and EBS; Cf disable is ok. 2) COS S_Vid/C_Vid + Priority Based: applied to a
SVLAN S_Vid and CVLAN C_Vid with priority range, CIR, EIR, CBS and EBS; Cf disable is ok.
Into switch there is a total of 64 instances of Input Filter Policing for all the four ports into any radio port.
Any CVID can be used into only one port.
Into same port same CVID can be reused but with different priority.
CIR (green)
EIR (yellow)
dropped (red)
CBS (green)
EBS (yellow)
dropped (red)
Содержание ALFOplus
Страница 1: ...ALFOplus Access Link Full Outdoor User Manual MN 00273 E 004 ...
Страница 16: ...14 MN 00273 E 004 ...
Страница 22: ...20 MN 00273 E 004 Fig 6 ALFOplus front side view 254 mm 254 mm 157 mm ...
Страница 86: ...84 MN 00273 E 004 ...
Страница 97: ...MN 00273 E 004 95 Fig 34 ODU with standard coupling kit O ring Coupling kit ...
Страница 98: ...96 MN 00273 E 004 Fig 35 1 0 ODU installation 3 1 2 ...
Страница 99: ...MN 00273 E 004 97 Fig 36 Polarization disk Reference ...
Страница 100: ...98 MN 00273 E 004 Fig 37 1 1 ODU installation 3 1 2 ...
Страница 101: ...MN 00273 E 004 99 Fig 38 1 0 antenna flange 4 3 4 1 2 5 114 60 ...
Страница 102: ...100 MN 00273 E 004 Fig 39 1 1 antenna flange 3 1 2 4 7 5 6 ...
Страница 109: ...MN 00273 E 004 107 Fig 49 Bend strain relief to lay along cable Crimp plug and strain relief ...
Страница 112: ...110 MN 00273 E 004 Fig 53 PO0032 ...
Страница 113: ...MN 00273 E 004 111 Fig 54 Connector positions Warning Tighten all unused connectors with the appropriate cover OK NO ...
Страница 118: ...116 MN 00273 E 004 Fig 58 ALFOplus connectors Fig 59 SFP LC LC Fig 60 SFP LC OPEN END ...
Страница 119: ...MN 00273 E 004 117 Fig 61 SFP LC SFP LC Fig 62 LC connector Fig 63 SFP into ALFOplus ...
Страница 120: ...118 MN 00273 E 004 Fig 64 Locked connection Fig 65 Unplug SFP ...
Страница 123: ...MN 00273 E 004 121 Fig 66 IP address setting Fig 67 Local area connection ...
Страница 144: ...142 MN 00273 E 004 Fig 82 Event log window ...
Страница 150: ...148 MN 00273 E 004 ...
Страница 220: ...218 MN 00273 E 004 ...
Страница 224: ...222 MN 00273 E 004 ...
Страница 230: ...228 MN 00273 E 004 ...